NetApp FAS2500 Скачать руководство пользователя страница 6

III.

Step  

10

a)

Enter: 

 to the question 

"Do you want to continue?"

.

11

Enter: 

cluster show 

 to display information about the nodes in the cluster.

12

Check the "Health" and "Eligibility" values for all nodes 

other than target node

 in all HA groups.  

Does any one show "false"?

If 

no

, go to step 13.

If 

yes

contact  

 NGS

 to correct the problem in the node showing 

false

 before moving into next step.

13

Check the Epsilon value for the 

TARGET

 node to be serviced.

If 

"true"

, go to step 14.

If 

"false"

, skip to step 15.

14

Follow steps (a-c) to reassign epsilon to a healthy node.  

(Also, See the example given below.)

a)

Enter: 

cluster modify -node <Target_node> -epsilon false

  to remove Epsilon from the target node.

b)

c)

Enter: 

cluster show

  to confirm that Epsilon has been re-assigned properly.

15

Enter: 

set -priv admin

  to return the privilege level to "admin".

16

Continue with Section III on next page.

NOTE: A typical 'cluster with only 1 HA-Pair (2-nodes)' uses 'cluster-
HA’ configuration and in that case Epsilon will show as "false" for 
both nodes.

Enter: 

cluster modify -node <Different_node_in_different_HA_Pair> -epsilon true  

to assign Epsilon to a node in a different HA-Pair.  

Page 5 of 25

FAS2500 Model : Node State Check and Shutdown Procedure (cont.)

 Action Description

Enter: 

set -priv advanced

  to set the privilege level to "advanced". 

(This is a required step to see the 'Epsilon' column in the next command output.)

Cluster::*> 

cluster modify -node Node_02 -epsilon false 

Cluster::*> 

cluster modify -node Node_04 -epsilon true 

Cluster::*> 

cluster show 

Node           Health  Eligibility   Epsilon
------------

------- ------------

------------

Node_01        true    true          false
Node_02        true    true          false

Node_03        true    true          false
Node_04        true    true          

true

In this example, Epsilon from Node_02 has been reassigned to Node_04, a 

node member of another HA-Pair.

Step to remove Epsilon 
from TARGET node.

Step to add Epsilon to 
different node.

Enter this command and verify the 
Epsilon has been re-added properly.

Cluster::>

set -priv advanced 

Warning: These advanced commands are potentially dangerous; use them only when

directed to do so by NetApp personnel.

Do you want to continue? {y|n}: 

y

Cluster::*> 

cluster show

Node           Health  Eligibility   Epsilon
------------

------- ------------

------------

Node_01        true    true          false
Node_02        true    true          

true

Node_03        true    true          false
Node_04        true    true          false

Example: 4-Node cluster  

Epsilon is seen on 4 or more node clusters. (A typical 2-node cluster doesn't use Epsilon.)

NOTE: A typical 'cluster with 

only 1 HA-Pair (2-nodes)' uses

'cluster-HA’ configuration and in 

that case Epsilon will show as

"false" for both nodes.

Enter this command to view node health and which node is holding epsilon (true).

Required step to see the 'Epsilon' column in the next command.

Boot Device Replacement for the FAS2500

For NetApp Authorized Service Engineers

Содержание FAS2500

Страница 1: ...an communicate with the service processor e0M port on the TARGET Have them test using ping bi directionally from the webserver and e0M port address Fix it if it fails AP doc rev is at top of page If u...

Страница 2: ...ion Capture the Current System Configuration Page 1 of 25 SECTION OUTLINE FAS2500 Model Appliance USB Boot Device Visual Checks Boot Device Replacement for the FAS2500 For NetApp Authorized Service En...

Страница 3: ...Check and Shutdown on next page FAS2500 Model Node Pre Checks Action Description Verify the Order Reference 8xxxxxxxxx number on the RMA packing slip is the same as the Part Request PREQ number listed...

Страница 4: ...th means the controller has some sort of FAULT 2 Fault LEDs on Rear What does this mean Both A B controllers are functioning properly OR both powered off OR one controller is functioning properly and...

Страница 5: ...nsole cable to the TARGET node and login 7 Mode root C Mode admin Engage end user for password If the Target node is not UP connect to the PARTNER node and login For 7 Mode options autosupport doit MA...

Страница 6: ...et priv advanced to set the privilege level to advanced This is a required step to see the Epsilon column in the next command output Cluster cluster modify node Node_02 epsilon false Cluster cluster m...

Страница 7: ...cf giveback auto enable off node options cf giveback auto enable cf giveback auto enable off node options cf giveback auto after panic takeover off node options cf giveback auto after panic takeover...

Страница 8: ...he PARTNER IF non HA and node is up engage end user to halt the TARGET node Once the takeover or halt is complete go to step 21 below Move console cable to the TARGET node if not already connected If...

Страница 9: ...The actual variable to look for is bootarg storageencryption support If this variable exists and is set to true then this is an NSE system STOP The printenv output is corrupt if there is any question...

Страница 10: ...nd only for Clustered ONTAP Type exit or Ctrl D to return to the CLI cm2554 ks 01 priv set advanced Warning These advanced commands are potentially dangerous use them only when directed to do so by Ne...

Страница 11: ...to section VI Replace the Boot Device on next page Page 10 of 25 FAS2500 Model Remove Cable Tray and Cables extract the MB Tray Action Description DO NOT turn off the power supplies because disks are...

Страница 12: ...Description Adhere to anti static precautions A paper ESD strap is included inside the RMA box if you don t have your own Align the new boot device with the boot device socket or connector and then fi...

Страница 13: ...to abort is displayed press Ctrl C C key a couple times to abort the autoboot See Console output example below FAS2500 Model Partially Reinsert the Controller and reconnect the cables Action Descript...

Страница 14: ...researched and manually entered Follow steps A C in Table 2 below Validate the Variable name and Value Enter printenv partner sysid Enter printenv bootarg init boot_clustered LOADER A printenv partne...

Страница 15: ...E enabled systems by following steps here a 10 a Enter savenv to save the variable s and value s 11 Go to section IX Prepare and Start the Netboot Process on next page Page 14 of 25 FAS2500 Model Boot...

Страница 16: ...if dns options were set If ping doesn t work recheck ifconfig settings and make sure the interface you configured is not on a private network or VLAN STOP and READ Table 3 on page 17 describes the pro...

Страница 17: ...ess Ctrl C for Boot Menu mkdir cfcard cores Read only file system The Boot Menu will be presented because an alternate boot method was specified Please choose one of the following 1 Normal Boot 2 Boot...

Страница 18: ...o this question now The correct response to this question depends on which procedure will be followed in Table 3 S T O P Extracting to cfcard x86_64 freebsd image2 Installed MD5 checksums pass Install...

Страница 19: ...estore Backup Configuration This procedure only applies to storage controllers that are configured as an HA pair Choose Yes to restore the varfs backup configuration from a SSH server Refer to the Boo...

Страница 20: ...a gateway to the TARGET node e0M If the restore backup fails below the disruptive method in Section XI must be used Was the restore backup procedure successful y n The restore configuration has been c...

Страница 21: ...nfiguration has been copied from the HA partner to this node would you like to use this restored copy now y n y Boot device dev da0 found Checking dev da0s1 file system success Mounting dev da0s1 to c...

Страница 22: ...to restore the varfs backup configuration from a SSH server Refer to the Boot Device Replacement guide for more details Choose No to skip the back up recovery and return to the boot menu Do you want t...

Страница 23: ...for giveback or if non HA to the login prompt Do not press Ctrl C during the boot process Boot Device Replacement for the FAS2500 For NetApp Authorized Service Engineers Starting AUTOBOOT press Ctrl C...

Страница 24: ...he TARGET node is booted up to a Waiting for giveback prompt press the enter key continue with step 3 Wait 90 seconds for 7 Mode or 3 minutes for Cluster Mode after giveback reported complete Check co...

Страница 25: ...t already connected and enter the proper controller giveback command s based on the mode running as follows Wait 90 seconds for 7 Mode or 3 minutes for Cluster Mode after giveback reported complete Ch...

Страница 26: ...g with NGS ask them if it is OK to be released 8 Close dispatch per Rules of Engagement Request end user to send NetApp an ASUP Message from the target node so the configuration setup can be verified...

Отзывы: