NetApp FAS2500 Скачать руководство пользователя страница 2

This procedure will take approximately

 2 hours

.

I.

Appliance / USB Boot Device Visual Checks

VIII.

Boot PROM Variable Checks

II.

Node Pre-Checks

IX.

Prepare and Start the Netboot Process

III.

Node State Check and Shutdown Procedure

X.

Transfer the System Files using 

Non

-Disruptive Procedure

IV.

XI.

Transfer the System Files using Disruptive Procedure

V.

Remove Cable Tray and Cables, extract the MB Tray

XII.

Boot the Operating System - 'giveback' if applicable

VI.

Replace the Boot Device

XIII.

Send Autosupport, Enable Options, Submit logs, Part Return

VII.

Partially Reinsert the Controller and reconnect the cables 

I.

Step  

1

The FAS2552 is a 2u model and FAS2554 is a 4u model. Review Figures below.

2

Continue with Section I on next page.

 Action Description

Capture the Current System Configuration 

Page 1 of 25

SECTION OUTLINE 

FAS2500 Model : Appliance / USB Boot Device Visual Checks

Boot Device Replacement for the FAS2500

For NetApp Authorized Service Engineers

2u

FAS2520, 2552

FAS2554

4u

PSU-1

IOIOI

(Console)

Controller Module

System Serial Number:  Each  
Controller Module Card (A or B) has 
it's own.  Verify the system serial 

SAS Ports: 

0b, 0a

Wrench port  

Management  (e0M), SP  

10/100/1000 Mb

"Locked" wrench 

Port ACP (e0P)

10/100/1000 Mb

1 Gigabit 

Ethernet:             

e0a, e0b

Fig 1

Fig 3

Controller Fault LED (Amber)

PSU-2

B

A

Fig 2: 

FAS2520,2552 Rear

A

Controller Fault LED (Amber)

PSU-1

PSU-2

PSU-4

PSU-3

B

Fig 4: 

FAS2554 Rear

Fig 5

AC Power

System Shelf ID

" ! "  LED is ON when  hardware failures are 
detected or if controller failover is disabled.

10Gb Ethernet:

e0c, e0d, e0e, e0f

FAS2520

FAS2552, 2554 (shown)

HA Configuration has 2 Controllers cards, 
(A & B) as shown.  A single controller 
system has only one card that is in slot A. 

Содержание FAS2500

Страница 1: ...an communicate with the service processor e0M port on the TARGET Have them test using ping bi directionally from the webserver and e0M port address Fix it if it fails AP doc rev is at top of page If u...

Страница 2: ...ion Capture the Current System Configuration Page 1 of 25 SECTION OUTLINE FAS2500 Model Appliance USB Boot Device Visual Checks Boot Device Replacement for the FAS2500 For NetApp Authorized Service En...

Страница 3: ...Check and Shutdown on next page FAS2500 Model Node Pre Checks Action Description Verify the Order Reference 8xxxxxxxxx number on the RMA packing slip is the same as the Part Request PREQ number listed...

Страница 4: ...th means the controller has some sort of FAULT 2 Fault LEDs on Rear What does this mean Both A B controllers are functioning properly OR both powered off OR one controller is functioning properly and...

Страница 5: ...nsole cable to the TARGET node and login 7 Mode root C Mode admin Engage end user for password If the Target node is not UP connect to the PARTNER node and login For 7 Mode options autosupport doit MA...

Страница 6: ...et priv advanced to set the privilege level to advanced This is a required step to see the Epsilon column in the next command output Cluster cluster modify node Node_02 epsilon false Cluster cluster m...

Страница 7: ...cf giveback auto enable off node options cf giveback auto enable cf giveback auto enable off node options cf giveback auto after panic takeover off node options cf giveback auto after panic takeover...

Страница 8: ...he PARTNER IF non HA and node is up engage end user to halt the TARGET node Once the takeover or halt is complete go to step 21 below Move console cable to the TARGET node if not already connected If...

Страница 9: ...The actual variable to look for is bootarg storageencryption support If this variable exists and is set to true then this is an NSE system STOP The printenv output is corrupt if there is any question...

Страница 10: ...nd only for Clustered ONTAP Type exit or Ctrl D to return to the CLI cm2554 ks 01 priv set advanced Warning These advanced commands are potentially dangerous use them only when directed to do so by Ne...

Страница 11: ...to section VI Replace the Boot Device on next page Page 10 of 25 FAS2500 Model Remove Cable Tray and Cables extract the MB Tray Action Description DO NOT turn off the power supplies because disks are...

Страница 12: ...Description Adhere to anti static precautions A paper ESD strap is included inside the RMA box if you don t have your own Align the new boot device with the boot device socket or connector and then fi...

Страница 13: ...to abort is displayed press Ctrl C C key a couple times to abort the autoboot See Console output example below FAS2500 Model Partially Reinsert the Controller and reconnect the cables Action Descript...

Страница 14: ...researched and manually entered Follow steps A C in Table 2 below Validate the Variable name and Value Enter printenv partner sysid Enter printenv bootarg init boot_clustered LOADER A printenv partne...

Страница 15: ...E enabled systems by following steps here a 10 a Enter savenv to save the variable s and value s 11 Go to section IX Prepare and Start the Netboot Process on next page Page 14 of 25 FAS2500 Model Boot...

Страница 16: ...if dns options were set If ping doesn t work recheck ifconfig settings and make sure the interface you configured is not on a private network or VLAN STOP and READ Table 3 on page 17 describes the pro...

Страница 17: ...ess Ctrl C for Boot Menu mkdir cfcard cores Read only file system The Boot Menu will be presented because an alternate boot method was specified Please choose one of the following 1 Normal Boot 2 Boot...

Страница 18: ...o this question now The correct response to this question depends on which procedure will be followed in Table 3 S T O P Extracting to cfcard x86_64 freebsd image2 Installed MD5 checksums pass Install...

Страница 19: ...estore Backup Configuration This procedure only applies to storage controllers that are configured as an HA pair Choose Yes to restore the varfs backup configuration from a SSH server Refer to the Boo...

Страница 20: ...a gateway to the TARGET node e0M If the restore backup fails below the disruptive method in Section XI must be used Was the restore backup procedure successful y n The restore configuration has been c...

Страница 21: ...nfiguration has been copied from the HA partner to this node would you like to use this restored copy now y n y Boot device dev da0 found Checking dev da0s1 file system success Mounting dev da0s1 to c...

Страница 22: ...to restore the varfs backup configuration from a SSH server Refer to the Boot Device Replacement guide for more details Choose No to skip the back up recovery and return to the boot menu Do you want t...

Страница 23: ...for giveback or if non HA to the login prompt Do not press Ctrl C during the boot process Boot Device Replacement for the FAS2500 For NetApp Authorized Service Engineers Starting AUTOBOOT press Ctrl C...

Страница 24: ...he TARGET node is booted up to a Waiting for giveback prompt press the enter key continue with step 3 Wait 90 seconds for 7 Mode or 3 minutes for Cluster Mode after giveback reported complete Check co...

Страница 25: ...t already connected and enter the proper controller giveback command s based on the mode running as follows Wait 90 seconds for 7 Mode or 3 minutes for Cluster Mode after giveback reported complete Ch...

Страница 26: ...g with NGS ask them if it is OK to be released 8 Close dispatch per Rules of Engagement Request end user to send NetApp an ASUP Message from the target node so the configuration setup can be verified...

Отзывы: