ses.status.displayError
Description
This message occurs when the SES module in the disk shelf detects an error in the disk
shelf display panel. The disk shelf might be unable to provide correct addresses to the disk
shelf.
Corrective action
1. If possible, verify that the connection between the disk shelf and the display is secure.
2. Verify that the SES module or modules are fully seated; replacing them might solve the
problem.
3. If the problem persists, the SES module that detected the error condition might be faulty.
4. If the problem persists after the module or modules are replaced, replace the disk shelf.
5. If the problem persists, contact technical support.
ses.status.displayWarning
Description
This message occurs when the enclosure services module detects a warning condition for
the disk shelf display panel. The disk shelf might be unable to provide correct addresses to
its disks.
Corrective action
1. If possible, verify that the connection between the disk shelf and the display is secure.
2. Verify that the SES module or modules are fully seated; replacing them might solve the
problem.
3. If the problem persists, the SES module that detected the warning condition might be
faulty.
4. If the problem persists after the module or modules are replaced, replace the disk shelf.
5. If the problem persists, contact technical support for assistance.
ses.status.temperatureError
Description
This message occurs when the indicated disk shelf temperature sensor reports a temperature
that exceeds the specifications for the disk shelf or its components.
Corrective action
1. Verify that the ambient temperature where the shelf is installed is within the vendor's
equipment specifications by using the
environment shelf [adapter]
command,
and check that airflow clearances are maintained.
For clustered systems, you must run this command from the nodeshell of the target
node.
2. If the same disk shelf also reports fan or fan module failures, correct that problem
immediately.
3. If the problem is reported by the ambient temperature sensor (located on the operator
display panel), verify that the connection between the disk shelf and the panel is secure,
if possible.
4. If the problem persists, and if the shelf has multiple temperature sensors but only one
exhibits the problem, replace the module that contains the sensor reporting the error.
5. If the problem persists, contact technical support.
DS4243, DS2246, DS4486, and DS4246 Installation and Service Guide
36
Monitoring disk shelf components