Appendix A: Hot-adding a Disk Shelf to an Existing System
59
10
If the disk shelf connects
to a...
Then change the disk shelf ID with
the following procedure...
System with Data ONTAP
7.x or earlier installed
1. Verify that the disk shelf ID is not
being used in the loop by entering
the following command at the
console
fcstat device_map
adaptername
Attention
An invalid disk shelf ID causes the
system to panic.
2. Press the thumbwheel switch on
the rear of the disk shelf and use
the + button to raise the number
and the - button to lower the
number to a valid ID from 1
through 7.
3. Select the correct label from the
envelope identified in
attach it to the right flange of the
new disk shelf.
Step
Action