Chapter 2: Monitoring the Disk Shelf
19
SES electronics
Element 2: component
is from a different
product family
Module B was replaced and the shelf has the
unsupported configuration of ESH2 and ESH4.
This error message occurs during the process of
hot-upgrading.
SES electronics
Element 1: failed
Module A on the top back of the disk shelf failed.
Contact technical support to replace the module.
SES electronics
Element 2: failed
Module B on the bottom back of the disk shelf
failed. Contact technical support to replace the
module.
Temperature sensor
Element 2: not
installed or failed
Communication was possible with the temperature
sensor on ESH2/ESH4 module A at one point, but
it is not possible now. Even if traffic is flowing
through the Fibre Channel loop, contact technical
support to replace the ESH2/ESH4.
Temperature sensor
Element 3: not
installed or failed
Communication was possible with the temperature
sensor on ESH2/ESH4 module B at one point, but
it is not possible now. Even if traffic is flowing
through the Fibre Channel loop, contact technical
support to replace the ESH2/ESH4.
SES electronics
Element 1: not
installed or failed
Communication was possible with ESH2/ESH4
module A at one point, but it is not possible now.
Even if traffic is flowing through the Fibre Channel
loop, contact technical support to replace the
ESH2/ESH4.
Vendor-specific
Element 1: not
installed or failed
SES electronics
Element 2: not
installed or failed
Communication was possible with ESH2/ESH4
module B at one point, but it is not possible now.
Even if traffic is flowing through the Fibre Channel
loop, contact technical support to replace the
ESH2/ESH4.
Vendor-specific
Element 2: not
installed or failed
Error message
Action required
Содержание DiskShelf14mk2 FC
Страница 12: ...6 Before you begin your installation For DS14mk2 FC ...
Страница 23: ...Chapter 2 Monitoring the Disk Shelf 17 For DS14mk2 FC ...
Страница 36: ...30 Monitoring the Fibre Channel disk For DS14mk4 FC ...
Страница 72: ...66 Hot adding a disk shelf to an existing adapter in your system ...
Страница 90: ...84 Index ...