Chapter 3: Replacing Disk Shelf Devices
49
Replacing an ESH2/ESH4 module
Removing a module
Assumption about
this procedure
This procedure is based on the assumption that the disk shelf is in a configuration
which fulfils one or all of the following requirements:
◆
It has a single path connection
◆
It is not in a cluster
◆
It does not use synchronous mirroring
Removing a module
To remove a module that is connected to the Fibre Channel loop, complete the
following steps.
Step
Action
1
Put on the antistatic wrist strap and grounding leash.
2
If the disk shelf
connects to a...
Then...
System with Data
ONTAP 7.x or earlier
installed
Shut down the system by entering the
following command at the console
halt
Attention
Always use the
halt
command to perform
a clean shutdown.