![NetApp DiskShelf14mk2 FC Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/netapp/diskshelf14mk2-fc/diskshelf14mk2-fc_hardware-and-service-manual_1669936048.webp)
42
Replacing a disk in a disk shelf
System with Data ONTAP
10.x installed
1. Log into the system and enter the
following command at the console
to go to the shell command mode:
ngsh
2. Enter the following command at the
console to go to the command line
interface:
dbladecli
3. If you are removing disk that is a
member of a volume, enter:
disk fail disk_name
Or:
If you are removing disk that is a
spare disk, enter:
disk remove disk_name
Either command causes the amber fault
LED on the disk to illuminate.
For more information about LEDs, see
“
Monitoring the Fibre Channel disk
2
Put on the antistatic wrist strap and grounding leash.
3
To remove the disk, press down on its release mechanism with one
hand while grasping the top flange of the disk shelf with the other
hand.
4
Gently slide the disk until it disengages. Wait 30 seconds for the disk
to stop spinning; then continue removing the disk from the chassis.
CAUTION
When removing a disk, always use two hands to support its weight.
5
If you are removing another disk, repeat