2.1.3. Summary of rules
We shall now provide a summary of the rules that
should be followed when building a chimney:
Use resistant and non-combus�ble materials for the
connection between the appliance and the chimney,
which are protected if possible against rust
(enamelled steel, stainless steel, …)
Choose the most vertical route possible.
Do not connect several devices to the same chimney.
The conduit should not come to an end near
buildings and must be higher than the nearest
obstacle if there is another building nearby.
The internal walls must be perfectly smooth and free
from obstacles.
Avoid bo�lenecks where pipes join the brick
chimney.
Ensure that the joints of the pipes are well sealed to
avoid air entering through cracks.
We recommend that enamelled stoves are installed
with the rear flue exit op�on.
2.2. Installation of the stove.
1. Posi�on the unit no closer than the minimum
clearances to combus�ble materials (see safety
chapter). Reposition unit if necessary, being careful
not to move closer than the minimum clearances.
2. Posi�on the unit on the floor at the proper
clearances. If the floor is made of combus�ble
material (for example, parquet) it must be protected
with a slab of fireproof material, placed under
the stove and around it. The size should be
such that it protrudes from the appliance: 20cm
back and sides and 50cm front.
3. Install the stove to the fireplace, sealing
it properly.
4. The stoves flue can never be connected to air
ducts or a ven�la�on system.
5. Appropriate
firebreaks/firewalls
must
be
installed
when
a
sec�on
of
the
chimney
passes
through
floors
and/or
ceilings.
The
insula�on
will
be
at
least
50mm
thick
from
the
flue
to
the
structure.
It
is
necessary
to
protect
the
walls
with
wall
protectors
when
the
chimney
is
not
at
the
indicated
safe
distance
and
damage
may
occur. (See
Fig.
2.)
Fig.2
DO NOT CONNECT THIS UNIT TO
A CHIMNEY FLUE SERVING ANOTHER
APPLIANCE.
Instruc�on Manual 08/2020
4 of 24
Fig. 3.- Chimney connection in a
fireplace
Cowl
Liner to top of
termina�on
and insulated
Flue liner
Flue liner
support collar
Weatherproof
cappin� and pot
Sound chimney
brick work
Flexible to sin�le
wall adapter
Re�ister plate,
posi�oned as
low as possible
to aid convec�on
Access for
cleanin�
Sufficient clearance, also for
maintenance and air circula�on
Total hei�ht
minimum of
4.5m
Thermal Insula�on
Chimney pipe
Ceiling