Important Notes:
With the introduction of SGIII there are some new methods of programming devices into the SGIII system. The
changes are due to the introduction of the Supervised and Encryption models of the Radio PIR, Radio Key, Radio
Reeds, Radio Panic\Duress buttons and Radio doorbell.
To place the SGIII into program mode simply power the unit by turning the EOR key to the ON position. The
display will show the version number for 0.5 second then flash “LEARN” for 10 seconds. During the 10 seconds
the display is flashing “LEARN”, press the “ON” button on any programmed key will enable the SGIII to receive
signals from radio devices (both keys and devices) “READY” will be flashing on the display.
The SGIII programs the device or key into the next available position. Eg. If there are already 4 sensors
programmed the next device will be programmed as sensor 5. If a sensor or key is deleted the next sensor or key
will be programmed in the position erased.
Programming details:
•
Programming Supervised / Encrypted PIR’s: Have the SGIII so “READY” is flashing on the display.
Connect the 9 volt Lithium battery. The SGIII will respond with “BING - BING - BING BING The display will
flash the sensor number programmed. Eg. “SENS 2” If you try to program the sensor into the SGIII by
triggering the sensor the SGIII will respond with “BING – BING – BBRRRR” Invalid tone. NOTE: The current
PIR’s Encryption feature is NOT operational at this time. DO NOT place a link on the ENCR link.
•
Programming Encrypted Radio Keys: Have the SGIII so “READY” is flashing on the display. Press and
HOLD the PANIC button. This sequence takes approx. 8 seconds, The SGIII will respond with a “BING”
when the panic message is received then “BING - BING - BING BING. The SGIII will flash the key number
programmed. Eg. “KEY 2” If you try to program the key by pressing the “OFF” button three times (like SGII)
the SGIII will respond with “BING – BING – BBRRRR” Invalid tone.
•
Programming Supervised / Encrypted Reed switches: Have the SGIII so “READY” is flashing on the
display. Connect the correct Lithium battery. The SGIII will respond with “BING - BING - BING BING The
display will flash the sensor number programmed including the Happy light. Eg. “SENS 2” If you try to
program the sensor into the SGIII by triggering the reed switch, the SGIII will respond with “BING – BING –
BBRRRR” Invalid tone.
•
Programming Supervised Panic Buttons: Have the SGIII so “READY” is flashing on the display. Connect
the correct Lithium battery. The SGIII will respond with “BING - BING - BING BING The display will flash the
Key number programmed including the Happy light. Eg. “KEY 6” If you try to program the panic button or
door bell into the SGIII by pressing the front button, the SGIII will respond with “BING – BING – BBRRRR”
Invalid tone. NOTE: Panic buttons are recognised as KEYS.
•
Programming Door Bells: Have the SGIII so “READY” is flashing on the display. Press and HOLD the BELL
button. This sequence takes approx. 6 seconds, The SGIII will respond with a “BING” when the Bell message
is received then “BING - BING - BING BING. The SGIII will flash the Door bell number programmed. Eg.
“KEY 7” NOTE: Door bells are recognised as KEYS.
Содержание Securityguard III
Страница 1: ...Doc ID SG3PROG00103_03_2014 DOC 1 Securityguard III Programming Guide Please Please Read Me ...
Страница 4: ...Doc ID SG3PROG00103_03_2014 DOC 4 ...
Страница 6: ...Doc ID SG3PROG00103_03_2014 DOC 6 ...
Страница 8: ...Doc ID SG3PROG00103_03_2014 DOC 8 ...
Страница 17: ...Doc ID SG3PROG00103_03_2014 DOC 17 Chime tone Warning tone ...
Страница 21: ...Doc ID SG3PROG00103_03_2014 DOC 21 9999 ...