SYSTEM ALARMS
System alarms are listed following, and are indicated by flashing the messages shown on the display
for 5 minutes. The siren also chirps for 3 seconds.
System alarms are not indicated when the system is in ARMED, HOME or HOME 2 modes.
See section 0 for details of corresponding voice messages. A time stamp is appended to each of the
following alarm messages when displayed (as shown is section 0).
DISPLAY
DESCRIPTION
BATTRY <
KEY
(or BUTTON
or MEDIC
or BELL) <
1-23
LOW BATTERY key or fixed panic button or medical
key or doorbell
Indicates a low battery condition. Low battery alarms
occur when a detector or a key operates with a low
battery.
BATTRY <
SENSOR <
2-23
LOW BATTERY detector
Indicates a low battery condition. Low battery alarms
occur when a detector or a key operates with a low
battery.
FAIL <
SENSOR < 1-
23
1. Non-supervised detector (existing)
A detector has not operated for 20 ARM/OFF
cycles. The detector should be checked to
ensure it is operating correctly.
2. Supervised detector (new for SGIII)
A radio supervisory message has not been
received from this detector for 4 hours. The
detector should be checked to ensure it is
operating correctly
Note: This alarm is only active if the SUPERVISED
DETECTORS option is enabled. FIRE detectors are
not checked.
OPEN <
SENSOR <
2-23
REED SWITCH: open on ARMING
A reed switch detector programmed for Check mode
operation was unsealed when entering ARMED,
HOME or HOME 2 modes. The detector should be
checked to ensure that it has sealed. Sound Warning
tone on ARMING (at end of EXIT DELAY).
LOW <
MAIN <
BATTRY
LOW BATTERY SecurityGuard
The main unit battery is load-tested on SecurityGuard
every 24 hours and when the system is disarmed. A
low battery condition is cleared immediately when
mains power goes from off to on.
DIALER <
RADIO <
FAIL
DIALLER RADIO FAIL
Indicates SecurityGuard was not able to
communicate with the dialler over the radio link.
DIALER <
POWER <
FAIL
DIALLER MAINS FAIL
Indicates AC mains to Dialler is not connected or
power is off
DIALER <
BATTRY <
LOW
DIALLER LOW BATTERY
Indicates battery on Dialler is missing, low, or unable
to hold charge
DIALER <
DIALLER CALL FAIL
Содержание Securityguard III
Страница 1: ...Doc ID SG3PROG00103_03_2014 DOC 1 Securityguard III Programming Guide Please Please Read Me ...
Страница 4: ...Doc ID SG3PROG00103_03_2014 DOC 4 ...
Страница 6: ...Doc ID SG3PROG00103_03_2014 DOC 6 ...
Страница 8: ...Doc ID SG3PROG00103_03_2014 DOC 8 ...
Страница 17: ...Doc ID SG3PROG00103_03_2014 DOC 17 Chime tone Warning tone ...
Страница 21: ...Doc ID SG3PROG00103_03_2014 DOC 21 9999 ...