background image

Doc ID. SG3PROG00103_03_2014.DOC

 

18 

 
RANGE DETECTOR RANGE 
(default = LOW
 

LOW 

Low range 8m 

HIGH 

High range 14m 

 
Note: OK light turns on each time PIR is activated. 

 
PULSE  

DETECTOR PULSE COUNT (default = 3

 

1-4 

Number of times (1-4) a detection beam needs to crossed before an alarm occurs 

Note: OK light turns on each time PIR is activated. 

 
SIGNAL  

SIGNAL CHECK: Check signal strength of radio detectors and keys 

 

SecurityGuard  registers  the  first  device  received  and  displays  the  signal  strength  (1-9),  and 
beeps a corresponding number of times. 

 

 

Press ON to activate Signal Check display shows “SEND DEVICE” 

 

For a key, press PANIC; for a detector, activate the detector 

 

Listen to beeps, view display 

 

Press OFF to exit Signal Check 

 

Press ON to re-activate Signal Check 

 

-- 

No detectors received 

SENS 2-23 

Detector x received 

KEY 1-23 

Key x received 

1-9 

Signal strength 

Note: OK light indicates main detector trigger 
 

RADJAM 

RADIO JAMMING (default = OFF) 

 
In the event of a SecurityGuard sensing a continuous (>30 secs) source of Radio Frequency 
Interference (RFI), it can generate a CHIME alarm in DISARMED or HOME or HOME 2 
modes, and a full alarm in ARMED modes. 
 

ON 

Enabled 

OFF 

Disabled 

 

 
RADSUB 

RADIO INTENTIONAL MESSAGE SUBSTITUTION (default = OFF) 

 
In the event of a SecurityGuard sensing a radio message with a recognised device ID but 
failing decryption, it can generate a CHIME alarm in DISARMED or HOME or HOME 2 modes, 
and a full alarm in ARMED modes. 
 

ON 

Enabled 

OFF 

Disabled 

 

Содержание Securityguard III

Страница 1: ...Doc ID SG3PROG00103_03_2014 DOC 1 Securityguard III Programming Guide Please Please Read Me ...

Страница 2: ...r arm and disarm doorbell fixed panic button supervised improved event memory locally accessible full up downloadable two push buttons on front of main unit providing volume control for voice internal beeps DEVICE CATEGORIES There are two categories of devices 1 Keys devices operated by buttons User key Medical key Doorbell Fixed Panic button 2 Detectors PIR Reed switch DEVICE ALLOCATION The allow...

Страница 3: ...ss enters HOME mode and a third ON press enters HOME 2 mode provided devices are programmed for these modes as detailed in the following sections ARMED Press ON button once to ARM the system Display ARMED Display for exit delay duration OK Light OFF Voice Armed If V ARM option enabled Siren 1 chirp internal at start of exit delay if V ARM option disabled and 1 chirp at end of exit delay 1 chirp ex...

Страница 4: ...Doc ID SG3PROG00103_03_2014 DOC 4 ...

Страница 5: ...icates SecurityGuard is functioning normally Voice Disarmed If V ARM option enabled Siren 3 chirps internal 3 chirps external if enabled and only if disarming from ARMED mode If alarm has occurred then disarming from ARM HOME or HOME 2 modes gives chirps Internal if V ARM option enabled then warning message after chirps if V ARM option disabled then rapid chirps for 5 seconds External rapid chirps...

Страница 6: ...Doc ID SG3PROG00103_03_2014 DOC 6 ...

Страница 7: ... light reverts to normal operation even if mains is still connected Main PIR trigger OK light turns on for a few seconds when PIR triggers in 1 PROGRAM mode when RANGE or PULSE selected 2 DISARMED mode after triggering in DISARM mode the main PIR is locked out for 4 minutes to conserve the battery similar to radio PIR s Reed switch Check mode programmed OK light turns on when device is selected in...

Страница 8: ...Doc ID SG3PROG00103_03_2014 DOC 8 ...

Страница 9: ...for events older than 24 hours 1 DAY 13 HRS AGO DISPLAY DESCRIPTION ALARM SENSOR 1 ALARM SecurityGuard integral detector ALARM SENSOR 2 23 ALARM from peripheral radio detector TAMPER SIREN BOX SIREN TAMPER Tamper is excluded if unsealed when powered up SIREN TAMPER EXCLUD is flashed on the status display and warning beeps sound to indicate tamper is excluded Arming and then Disarming the system wi...

Страница 10: ...l detected RADIO TAMPER Radio intentional message substitution detected Event Log Intruder alarm events are logged in memory and displayed with the time elapsed since the alarm occurred In DISARMED mode press OFF to step through the log Once all logged alarms have been displayed pressing OFF will clear the display Pressing OFF again will redisplay the first event in the log etc To clear the log en...

Страница 11: ...re it is operating correctly 2 Supervised detector new for SGIII A radio supervisory message has not been received from this detector for 4 hours The detector should be checked to ensure it is operating correctly Note This alarm is only active if the SUPERVISED DETECTORS option is enabled FIRE detectors are not checked OPEN SENSOR 2 23 REED SWITCH open on ARMING A reed switch detector programmed f...

Страница 12: ... to 5 events If the log is full logging a new event causes the oldest event to be discarded Events older than 100 days will be discarded ENTRY EXIT DELAY EXIT DELAY is the time between pressing the ON button to system ARMED during which detector activations are ignored The siren will chirp once when the ON button is pressed to indicate EXIT DELAY start and chirp once at exit delay end to indicate ...

Страница 13: ...t device will be sent to the central station until the system is DISARMED and ARMED This feature prevents a large customer phone bill being incurred if for example a door protected by a reed switch is left unlatched and swings open and shut many times Runaway is permanently enabled PROGRAMMING SGIII is programmed in a similar way to SGII The main difference is in the way radio devices are programm...

Страница 14: ...on is displayed flashing when viewed Various beeps as per SGII give audible feedback during the programming process Press OFF on a programmed key to step through the devices options Press ON to view the value for that option The programmed value will be displayed flashing Press the ON button to step through alternative values which will be displayed steady Press the PANIC button to store the displ...

Страница 15: ...answers a call but does not verify within 30 seconds it will hang up Once a connection is established the Dialler will unconditionally hang up after 5 minutes if a hang up is not requested sooner by the remote end 3 Once a connection is established program the SGIII Radio Dialler system as required 4 SGIII will exit PROGRAM mode when the Up down connection is terminated or when the SGIII PROGRAM m...

Страница 16: ...per existing close reed for Check mode open reed for non Check mode operation OK light turns on when Check mode operation successfully programmed Non encrypted non restoring detector e g PIR Activate detector 3 times SecurityGuard beeps each activation and gives 2 beeps when code accepted and flashes SENS 2 23 Encrypted restoring detector e g reed switch Power the detector off then on by momentari...

Страница 17: ...Doc ID SG3PROG00103_03_2014 DOC 17 Chime tone Warning tone ...

Страница 18: ...tector activate the detector Listen to beeps view display Press OFF to exit Signal Check Press ON to re activate Signal Check No detectors received SENS 2 23 Detector x received KEY 1 23 Key x received 1 9 Signal strength Note OK light indicates main detector trigger RADJAM RADIO JAMMING default OFF In the event of a SecurityGuard sensing a continuous 30 secs source of Radio Frequency Interference...

Страница 19: ...es not receive a signal for X consecutive hours then a warning will be displayed 1 4 8 16 2 4 Supervision alarm occurs if no supervisory message is received within set period in hours OFF Supervision alarms disabled LOKOUT DETECTOR LOCKOUT default OFF If DETECTOR LOCKOUT is enabled all devices will only sound the external siren the first time they alarm Any subsequent alarms from these detectors w...

Страница 20: ...itoring station each time the system is ARMED or DISARMED including which user user ID operated the system ON Enabled OFF Disabled LOWBAT LOW BATTERY REPORTING default NONE NONE No low battery reporting MAIN Report low main battery SENSOR Report low detector batteries ALL Report low main and detector batteries CLIENT CLIENT ACCOUNT NUMBER default 0000 After a period of 30 days following PROGRAM mo...

Страница 21: ...Doc ID SG3PROG00103_03_2014 DOC 21 9999 ...

Страница 22: ...after the fourth digit is entered Press ON to store the last digit then press OFF The programmed phone number will scroll across the display after which 2 beeps will occur and the first digit will be flashing Press OFF to step to next option or repeat procedure to make corrections PHONE2 PHONE NUMBER 2 default Same as PHONE NUMBER 1 ABORT DIALLER ABORT DELAY default 15 Gives the opportunity to abo...

Страница 23: ...rt of PROGRAM mode displaying KEY 1 ALL Erases all programmed devices and defaults all options OPTION Defaults all option values KEY Erases all keys SENSOR Erases all detectors defaults SENSOR 1 main PIR P EXIT PROGRAM MODE EXIT CONTINUE Press ON to exit PROGRAM mode Press OFF to step to first program option If the OFF button is pressed LEARN will be displayed By then pressing ON READY will be fla...

Страница 24: ...the customer The client account number must be programmed into the system New alarms initiate a dial out report Alarms are deemed to be restored when the OFF button on a programmed key is pressed The dialler reports alarms to a central monitoring station in Contact ID format see section CONTACT ID REPORTING This reporting is used to transmit alarms from a subscriber s site to a central monitoring ...

Страница 25: ...mming 105 SUPVIS not OFF 355 Radio supervision poll fail Device 200 ID LOWBAT MAIN LOWBAT ALL 302 Main unit low battery 107 LOWBAT SENSOR LOWBAT ALL 384 Radio device low battery 0 ID OPEN ON 401 Open Close with user ID 0 ID T CALL not OFF 602 Test call 104 Always enabled 406 Cancel of alarm message 0 ID Radio Dialler The following events are initiated by the Radio Dialler Program Option Event Code...

Страница 26: ...d Voice enabled 1 Status ARMED DISARMED etc Entering ARMED mode Start of exit delay chirp Armed End of exit delay chirp chirp Entering HOME HOME 2 mode Start of exit delay chirp HOME or HOME 2 armed no external chirps even if enabled End of exit delay chirp chirp Disarming from ARMED mode chirp Disarmed Disarming from HOME HOME 2 mode chirp Disarmed no external chirps even if enabled 2 Alarm event...

Страница 27: ...ck for cause of radio interference Radio Message Substitution Radio tamper detected Check for cause of radio interference 3 Low battery System in any mode all events Disarming system or step through event log entries by pressing OFF button Main unit chirp chirp followed by Low battery in main unit Plug in battery charger for twenty four hours Radio Device chirp chirp followed by Low battery in key...

Страница 28: ...aller fail Check dialler Dialler Mains Fail chirp chirp followed by Dialler power fail Check dialler power Dialler Call Fail chirp chirp followed by Dialler could not contact monitoring station Check for dial tone Check dialler telephone line plugged in Dialler Line Fault chirp chirp followed by Dialler telephone line fault Check for dial tone Check dialler telephone line plugged in 5 FAI sales pr...

Страница 29: ...ink on the ENCR link Programming Encrypted Radio Keys Have the SGIII so READY is flashing on the display Press and HOLD the PANIC button This sequence takes approx 8 seconds The SGIII will respond with a BING when the panic message is received then BING BING BING BING The SGIII will flash the key number programmed Eg KEY 2 If you try to program the key by pressing the OFF button three times like S...

Страница 30: ... This will allow you to hear the dialler call and respond to the central station tones and then hang up after sending the message Don t forget to remove the link on J6 after testing to the central station To test SGIII to Radio dialler signal strength from this point on simply put the SGIII into program mode Cycle through until P EXIT is on the display then press the ON button on any programmed ke...

Отзывы: