Doc ID. SG3PROG00103_03_2014.DOC
12
CALL <
FAIL
Indicates dialler was not able to successfully contact
the monitoring station.
DIALER <
LINE <
FAULT
DIALLER LINE FAULT
Indicates minimum telephone line DC voltage was not
detected for over 2 minutes.
Event Log
System alarm events are logged in memory.
In DISARMED mode, press OFF to step through the log. Once all logged alarms have been displayed,
pressing OFF will clear the display. Pressing OFF again will redisplay the first event in the log, etc.
Entries in the log will cleared only when the cause of the alarm has been rectified, or when power is
turned off using the key switch.
The alarm event log will store up to 5 events. If the log is full, logging a new event causes the oldest
event to be discarded. Events older than 100 days will be discarded.
ENTRY & EXIT DELAY
EXIT DELAY is the time between pressing the ON button to system ARMED, during which detector
activations are ignored. The siren will chirp once when the ON button is pressed to indicate EXIT
DELAY start and chirp once at exit delay end to indicate ARMED.
Warning tone at the end of EXIT DELAY indicate a reed switch is unsealed, displayed as specified.
ENTRY DELAY is the time between a detector activation to system DISARMED, during which detector
activations do not cause an alarm. During ENTRY DELAY the siren will chirp once a second. When
the OFF button is pressed the siren chirps 3 times to indicate DISARMED. If the OFF button is not
pressed within the ENTRY DELAY, the siren sounds and strobe flashes.
Содержание Securityguard III
Страница 1: ...Doc ID SG3PROG00103_03_2014 DOC 1 Securityguard III Programming Guide Please Please Read Me ...
Страница 4: ...Doc ID SG3PROG00103_03_2014 DOC 4 ...
Страница 6: ...Doc ID SG3PROG00103_03_2014 DOC 6 ...
Страница 8: ...Doc ID SG3PROG00103_03_2014 DOC 8 ...
Страница 17: ...Doc ID SG3PROG00103_03_2014 DOC 17 Chime tone Warning tone ...
Страница 21: ...Doc ID SG3PROG00103_03_2014 DOC 21 9999 ...