ENROLLING:

1.

Press the ELK key, then press 9 (or scroll up) to display 9 - Installation Programming.
Press the RIGHT arrow key to select this menu.  The Installer Program Code (PIN) must be
entered to access this menu.

2.

Enter the Installer Program Code.  (See M1 Manual for the default Code)

3.

The first Installer Programming menu displayed will be “Bus Module Enrolment”

4.

Press the RIGHT arrow key to select this menu.  “Enrolling Bus Modules” will display

5.

The M1 transmit an enrolment message to all data bus devices, following by a display
showing the total Bus Modules that are enrolled.  To view the enrolled devices and/or
remove a device press the RIGHT arrow key next to the word Edit.

6.

Press the * or Exit keys to exit Installer Programming.

(Optionally the modules can be enrolled into the system using the NessRP software)

NEG  

-

DATA B

+12V

DATA BUS

+VKP

DATA B

DATA A

NEG
EGND

J1

J2

RE: Data Bus Termination Note

DATA BUS TERMINATION IS VERY IMPORTANT!!

Ideal setup is 2 home run cables (4 wire) with daisy chained devices along each. The last device on each cable MUST have
a Terminating resistor installed (activated) via the gold 2 pin header/jumpers marked JP2 on keypads, JP1 on expanders.
Place a black shorting cap (see hardware pack) onto the 2 gold pins to install a 120 Ohm resistor across data lines A & B.
NOTE: Place a shorting cap on JP3 of Main Board it there is only 1 data bus cable.  See diagrams on multiple cables.

Temporary Connection "Plug-in" jacks for RS-485 Data Bus (J1 & J2)

Local connection for Data Bus Devices ie: Keypads, etc. for testing purposes only.

ELK-M1KP

BLACK

WHITE

GREEN

JP3 Teminating Jumper

(Located beneath cover)

RS-485 Data Bus

  (Max. length is 4000 ft.

Max. bus devices vary by control.)

WARNING!  The RS485 Data Bus must NEVER have more that two (2) terminating resistors

header/jumpers installed.    Reliability and response will be negatively affected!

RS-485 DATA BUS

DATA A

RED

ELK-M1XIN

ELK-M1XOV

Jumper

Terminate

these two

devices.

DO NOT Jumper

Terminate these devices.

Keypad 1

ELK-M1KP

Keypad 2

ELK-M1KP

Keypad 3

Diagram for Daisy Chain Connection of Data Bus Devices Using Two (2) Home Run Cables

The ideal way to connect multiple home run cables is with an ELK-M1DBH Data Bus Hub.  It accepts CAT5 or CAT6 cable with RJ45 plugs on the ends.

It does all the work of series connecting the DATA lines A & B and provides a clean, organized management of the data bus wires.

Data Bus E.O.L. Termination is Very Important

INSTALLATION AND ENROLLMENT OF NESS-M1RF RECEIVER

Select a suitable location for the receiver (not within a metal cabinet) with an ambient temperature range between 0

°

and 49

°

 C (32° to +120

°

 F).

The Ness M1RF Receiver connects onto the M1 data bus, which uses 4-wires.  However, CAT5 or CAT6 eight (8)
conductor is recommended for all data bus cables.  The extra wires are for data return paths. If cable is to be installed
in installations where electrical noise maybe present then a twisted pair shielded cable should be considered.  

NOTE:

See pages 12 and 13 in the M1 Installation Manual for important information about Data Bus termination
when multiple homerun cables are installed.

 

 DO NOT SPLICE OR CONNECT WIRE WITH CONTROL POWER

ON.

  Minimum cabling should be four conductor 22 or 24 gauge.  Maximum resistance per wire is 25 Ohms. Device

placement beyond 305 mts (1000 feet) is not recommended.

Setting the Data Bus Address and Enrolling Device(s) into the System

Keypads and expander devices communicate with the M1 over the RS-485 4-wire data bus.  Each device must have
a unique address setting (from 1 to 16) within it's device type.  Keypads are device TYPE 1, input (zone) expanders
& Wireless RF Receivers are TYPE 2, output expanders TYPE 3, etc.  The purpose of device types is so that the
address numbers can be re-used in each different device type.  It is acceptable to have a Keypad, and a Zone
Expander, and a Output Expander all set to address 2 and on the same data bus since each device is a different
device type.

It is NOT acceptable to have duplications of addresses within the same device type.  I.E. Multiple keypads
on the same control cannot be set to 'like' addresses.
ADDRESS SETTING:

  Locate the four "Address" switches.  Each has a position of OFF or ON  (binary 0 or 1)

with a decimal equivalent of (1, 2, 4, or 8).  The total decimal value for the "ON" switches sets the bus address.
This determines which inputs (banks of 16) are assigned to the expander.  E.G. Address 5 would be set with
switches 1 and 4 ON (1+4=5) and switches 2 and 3 OFF.  RF Receivers are factory pre-set to address 2.

Note 1: A Wireless Receiver is a type 2 bus device, therefore it is treated and looks to
the system as an Input Expander.
Note 2: It is possible to use more than 1 Wireless Receiver per system. This increases
the range available to receive wireless devices. If more than one is used then ensure
they are all set at different address.

Содержание M1RF

Страница 1: ...Page 1 INSTALLATION MANUAL Ness M1RF Wireless Receiver Specifications Installation and Programming Ness Document No 895 364 Version 1 4 May 2008 ...

Страница 2: ...the 4 Wire Data Bus DIP Switch Address Settings Flash Memory for Firmware Updating Status and Diagnostic LED On Board EOL Bus Termination Jumper Supplied in easy to mount equipment housing The Ness M1RF receiver is compatible with the following Wireless transmission devices at initial release Ness R15 PIR 100 663 Ness R15 PET 100 663PET Ness R12 PIR 100 691 Ness RR1 Radio Reed 100 662 Ness RR2 Uni...

Страница 3: ...nes A B and provides a clean organized management of the data bus wires Data Bus E O L Termination is Very Important INSTALLATION AND ENROLLMENT OF NESS M1RF RECEIVER Select a suitable location for the receiver not within a metal cabinet with an ambient temperature range between 0 and 49 C 32 to 120 F The Ness M1RF Receiver connects onto the M1 data bus which uses 4 wires However CAT5 or CAT6 eigh...

Страница 4: ...er module for the zone to be allocated for wireless Note You can add assign more than 16 zones of wireless on one wireless receiver by adding more wireless expanders and allocating more groups to wireless If the group is greyed out then those zones will already exist in this account Once zones have been allocated as Wireless Zones the Input module will be shown as a Wireless rather than a Input Ex...

Страница 5: ... M1 voice is enabled not available on M1 EZ8 systems the system will provide voice prompts and feedback of enrolment If the voice prompt speaks Press Transmitter button for If the zone prompt does not speak a Voice description then it is will be because you have not entered one in for the Zone beingenroled Once enrolled the system will automatically move to learn mode of the next zone If a zone ha...

Страница 6: ...tters have been learnt into the M1 their data can be uploaded to NessRP RIGHT mouse click on Wireless Setup and then select Receive Wireless Setup Once data has been received their Tx ID s can be viewed when wireless Transmitters tab is selected ...

Страница 7: ...the radio key to be set to This can be User 1 255 excluding 200 203 as these are reserved Tx ID or DL This is the Radio Transmitters unique ID If this ID is known e g learnt in and recorded from another test system it can be manually entered and downloaded into the M1 which will allow the transmitter to work To change setting in the transmitter settings click on the Zone and then change Deleting T...

Страница 8: ...etailed below to set buttons on each keyfob Ness Security Products Pty Ltd Sydney 02 8825 9222 Melbourne 03 9875 6400 Brisbane 07 3399 4910 Perth 08 9328 2511 Adelaide 08 8152 0000 email m1support ness com au Ness Document No 895 364 Programming Individual Buttons on Radio Keys each key Using rules programming within the M1 each button on each radio key can be programmed individually as the follow...

Отзывы: