15
TESTING AND TROUBLE SHOOTING
TESTING ******************************************************************************************************
To ensure the integrity of your security system,
WALK TEST
it should be checked on a regular basis.
To check correct operation of all zones
YOU can carry out any of the tests outlined
(indicated by a 2 second siren and beeper
below or engage a qualified Technician from a
warning).
licensed Alarm Company to carry out a more
technical assessment according to Australian
NOTE: Programming described in steps 14 are
Standards AS.2201.1
normal default values. Therefore these steps
may be bypassed if Monitor mode is not being
used and has not been reprogrammed.
9.2 MAINTENANCE (extract AS.22O1.1)
9.2.1 Routine maintenance.
1. Enter Program mode
P (CODE) E
9.2.1.1 General Routine maintenance visits to the
2. Select Monitor mode 2
P 7E 2E
alarmed premises shall be made by an authorised
3. Set all the zones to Monitor zones.
representative of an alarm company at a minimum
rate of twice per year with no more than 7 months
P 8E 1E 2E 3E 4E 5E 6E 7E 8E.
between visits.
(Select only those zones whose lights are not lit.)
Remember: If your system is connected to a
4. Exit the client Program mode PE
Central Monitoring station, please advise them
prior to carrying out any of these tests.
Ensure that all zones are secured and then,
SIREN TEST
5. Select Monitor mode.
8E.
- Enter 2 E, Siren will sound
Now move around your premises and
unsecured each detector in turn. The siren will
- To reset siren Enter (CODE) E.
operate for 2 seconds each time a detector is
unsealed.
When you have tested all detectors, check the
SYSTEM CHECK
control panel to ensure that all zone indicators
are flashing ie. all zones have been tested.
-ARM Panel. 0E or O (CODE) E.
6. EXIT FROM MONITOR MODE by disarming
-Wait for exit time to expire - trigger any
the panel.
Instant zone and the siren should sound, OR
trigger a Delay zone - wait for the entry time to
7. Don't forget to re-program the Monitor
expire and the siren should sound
mode type, and Monitor zones back to their
normal settings.
- Reset the panel (CODE) E.