TRICON/E/E2/E3 Transmitter Installation and Maintenance Guide
2-3
Move the cover far enough down the cable to allow you to work with the
end that you just inserted.
4.
Strip the outer covering of the cable back approximately 1-1/2” from the
inserted end.
5.
Separate the individual conductors and strip the insulation back
approximately 1/2” from the end of each conductor.
6.
Using the rounded shaft of the screwdriver, form a hook in the end of each
bare copper wire. (See Figure 2.3.)
7.
Loosen the terminal screws, as shown in Figure 2.4.
8.
Position the wire hook of each conductor under the proper terminal screw
according to the appropriate wiring diagram.
Refer to Figure 2.5 and Table 2.1 for the wiring diagram.
Figure 2.2 Inserting Multi-Conductor Cable
Figure 2.3 Creating a Hook in the Wire
Figure 2.4 Connecting the Conductors to the Terminal Screws