3-6
TRICON/E/E2/E3 Transmitter Installation and Maintenance Guide
Meter Size
Maximum
Number of
Pulse Output
Flow Range
(in)
Continuous
Pulses per
@ Maximum
of 4-20mA
Flow Rate (gpm)
Gallon
1
Flow Rate (Hz)
1
Output (gpm)
4”
1,200
7.556
151.2
0 – 1200
6
2,500
0.7556
37.78
0 – 2.888
8
4,000
0.6095
40.63
0 – 4,959
10
6,500
0.5333
57.78
0 – 9,209
Table 3.10 4”, 6”, 8”, and 10” HP Protectus III Turbine Elements Performance Specifications
2
1
For the
High-Resolution Output
of the TRICON/E2 transmitters, multiply these values by
9
and for the
TRICON/E3, multiply these values by
10
.
2
Note: This table is based on mounting HPT TRICON/E3 on the same size HP Protectus III Turbine Element.