1520
IF ITEM% <> 2 THEN 1550
1530
IF ITEM% =2 THEN IF DR=0 THEN DR= 1 ELSE DR=0
1540
IF ITEM% = 2 THEN 1230
1550
IF ITEM% <> 3 THEN 1580
1560
IF ITEM% = 3 THEN IF DT=0 THEN DT=1 ELSE DT =0
1570
IF ITEM%= 3 THEN 1230
1580
IF ITEM% <> 4 THEN 1610
1590
IF ITEM% =4 THEN IF PA=0 THEN PA=1 ELSE PA=0
1600
IF ITEM%= 4 THEN 1230
1610
IF ITEM% <> 5 THEN 1690
1620
IF ITEM%= 5 THEN IF PAS=0 THEN PAS=1 ELSE PAS-0
1630
IF ITEM% = 5 THEN 1640
1640
LOCATE 23,
1650
PRINT STRING$ (79, 32)
1660
LOCATE 23,
1670
INPUT “LOAD WITH WHAT VALUE (PRESS ENTER IF DESELECTING 5) “, PASN$
1680
GOTO 1230
1690
IF ITEM% <> 6 THEN 1720
1700
IF ITEM% = 6 THEN IF PB=0 1 ELSE PB=0
1710
IF ITEM% = 6 THEN 1230
1720
IF ITEM% >7 THEN 1230
1730
IF ITEM% = 7 THEN IF PBS=0 THEN PBS=1 ELSE PBS=0
1740
IF ITEM% = 7 THEN 1750
1750
LOCATE 23,
1760
PRINT STRING$ (79, 32)
1770
LOCATE 23,
1780
INPUT “LOAD WITH WHAT VALUE (PRESS ENTER IF DESELECTING 7) “, PBSN$
1790
GOTO 1230
1800
CLS
1810
PRINT “COMMUNICATIONS ARE BEING OPENED WITH THESE PARAMETERS:”
1820
LOCATE 4,
1830
PRINT ,, COMFIL$
1840
'__________________________________________________________________________________________________________
__________
1850
“SEND A CARRIAGE RETURN TO CLEAR THE SmartTrol (ASCII 13). POLL SmartTrol TO ACTIVATE
COMMUNICATIONS.
1860
“SEND SELECTED COMMANDS. SUPPRESS UNWANTED CARRIAGE RETURNS BY ENDING PRINT
STATEMENT WITH A SEMICOLON.
1870
'__________________________________________________________________________________________________________
__________
1880
PRINT #1, CHR$ (13) ;
1890
PRINT #1, “D” = UN$ + CHR$ (32);
1900
'__________________________________________________________________________________________________________
__________
1910
‘ ENTER ROUTINE THAT DETERMINES THE CURRENT SECOND OF TIME AND HOLDS THE PROGRAM
UNTIL SECONDS CHANGE TWICE. THE HOLD OF 1 TO 2 SECONDS ALLOWS SmartTrol TO RECEIVE
TRICON
®
SmartTrol
™
Installation and Maintenance Guide
59
Appendix B: Communications Program
Содержание TRICON SmartTrol
Страница 1: ...TRICON SmartTrol Installation and Maintenance Guide...
Страница 2: ......
Страница 3: ...TRICON SmartTrol Installation and Maintenance Guide...
Страница 8: ...This page intentionally left blank vi TRICON SmartTrol Installation and Maintenance Guide Contents...
Страница 10: ...This page intentionally left blank viii TRICON SmartTrol Installation and Maintenance Guide Figures...
Страница 14: ...This page intentionally left blank Chapter 1 Introduction 2 TRICON SmartTrol Installation and Maintenance Guide...
Страница 56: ...This page intentionally left blank Chapter 12 Warranty 44 TRICON SmartTrol Installation and Maintenance Guide...
Страница 58: ...This page intentionally left blank Chapter 13 Assistance 46 TRICON SmartTrol Installation and Maintenance Guide...
Страница 76: ...This page intentionally left blank Appendix C TRICON S 64 TRICON SmartTrol Installation and Maintenance Guide...
Страница 83: ...Glossary VDC Direct Current Voltage TRICON SmartTrol Installation and Maintenance Guide 71...
Страница 84: ...This page intentionally left blank 72 TRICON SmartTrol Installation and Maintenance Guide Glossary...
Страница 88: ...76 TRICON SmartTrol Installation and Maintenance Guide Index This page intentionally left blank...
Страница 89: ......