![Neptune Technology R450 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/neptune-technology/r450/r450_installation-and-maintenance-manual_1668316031.webp)
R450 Data Collector Installation and Maintenance Guide
11
Chapter 2: General Installation Guidelines
This chapter describes the specifications for the R450 Data Collector (R450 DC),
storage, unpacking instructions, preliminary tests, tools, materials, site selection, and
installation of the R450 DC.
R450 DC Specifications
This section provides the specifications of the R450 DC.
Electrical Specifications
AC Power
120 AC, 1.0A, 60Hz
Power Consumption
50 Watts
Environmental Conditions
Operating Temperature
1
-22° to 140°F (-30° to 60°C)
Storage Temperature
-40° to 185°F (-40° to 85°C)
Operating Humidity
0 to 95% Non-condensing
Environmental Rating
UL50E Type 4X
Operating Altitude
Less than 6561 feet (2000 meters)
1
For installations that have ambient temperatures that exceed 110°F (43.3°C), the R450 DC must be
installed in a well-ventilated, shaded location.
Mechanical Specifications
Maximum Weight
71.5 lbs (32.5 kg)
R450 DC Footprint
R450 DC
8' x 8' Triangle
Stand (Valmont)
2.4M x 2.4M Triangle
Safety Approval
UL Listed
Per 60959-1
CSA c222
No. 60950-1
Содержание R450
Страница 2: ......
Страница 3: ...R450 Data Collector Installation and Maintenance Guide ...
Страница 8: ...This page intentionally left blank ...
Страница 18: ...This page intentionally left blank xvi R450 Data Collector Installation and Maintenance Guide Tables ...
Страница 20: ...This page intentionally left blank xviii R450 Data Collector Installation and Maintenance Guide Tables ...
Страница 143: ......