«Neomatica» Wireless sensor-immobilizer ADM33, edition 1.1 dd 11.11.2019
15
5.
Command description
Command
Answer
Parameters
Description
1
be
be
Command without parameters
Switch to firmware update mode
2
ds
ds
Command without parameters
Reset to the factory settings
3
rs
rs
Command without parameters
4
rb
rb
Command without parameters
5
wf
wf
Command without parameters
Save settings
6
cp X
cp
X – password. Consists only of Arabic numerals
Password change
7
сr X
cr
X – operation mode
0 – electromechanical relay;
1 – semiconductor switch (only output 1);
2 – semiconductor switch (only output 2);
3 – semiconductor switch (outputs 1 and 2).
Select immobilizer operation mode
8
br Х
br
Х – immobilizer status
0 – COM+NC (by default);
1 – COM+NO.
Select initial immobilizer status after
power switch on
9
ar Х
ar
Х – immobilizer status
0 – COM+NC;
1 – COM+NO (by default).
Select emergency status of immobilizer
10 ts
ts
Х – types of actions:
0 – do nothing;
Action to be performed at the absence of
connection with the tracker.