rs: [parameter ID]=[parameter value];[parameter ID]=[parameter value] and etc.
List of parameters ID :
12 — protection against messages substitution from controlling tracker (
sf
command
is used)
13 — mode of immobilizer operation (
cr
command is used)
14 — initial status of immobilizer (
br
command is used)
15 — emergency status of immobilizer (
ar
command is used)
16 — actions, action to be done when connection with the tracker is lost (
ts
command
is used)
17 — frequency of control messages receipt from the tracker, in the status of
immobilizer setting (
ad
command is used)
18 — time of signal waiting from the tracker after which the connection is considered
to be lost. (
ta
command is used)
19 — inversion of the status of electromechanical relay and semiconductor switches.
(
ri
command is used)
•
To read service information use
rb
command.
The command sends response in the following form:
rb: [parameter ID ]=[parameter value];[parameter ID ]=[parameter value] and etc.
List of parameters ID:
1 — main firmware version.
2 — firmware version.
3 — type of device.
4- configuration version