 «Neomatica» Wireless sensor-immobilizer ADM33, edition 1.1 dd 11.11.2019        

 

 

Fig. 3. ADM33. Scheme of external blocking relay connection.  

 

4.1.2. 

Electromechanical relay mode 

 

In such a mode the outlets «СOM», «NC», «NO» are considered to be the outlets of 

electromechanical relay with switching group of contact elements.  

Common outlet “COM” is switched to the outlet “NC” or to the outlet “NO”.  When the 

voltage is not supplied to the electromechanical relay coil as well as to the immobilizer then 

outlet “NC” is closed to the outlet “COM”. 

Functions of the outlets in electromechanical relay mode are indicated in figure 4.   

 

 

 

Fig. 4. ADM33. Scheme of contact elements when using electromechanical relay 

 

1. 

Red cable — + (plus of the power source); 

2. 

Black cable — GND (minus of the power source); 

3. 

Blue cable — COM (common contact element); 

4. 

White cable — NO (normally-open contact element); 

5. 

Brown cable — NC (normally-closed contact element). 

Содержание ADM33

Страница 1: ...Neomatica Wireless sensor immobilizer ADM33 edition 1 1 dd 11 11 2019 1...

Страница 2: ...ectromechanical relay mode 9 4 2 Immobilizer operation with the tracker ADM333BLE 10 4 2 1 Connection of immobilizer to the tracker 10 4 2 2 Control of immobilizer statuses 11 4 2 3 Setting immobilize...

Страница 3: ...is designed for professionals who have familiarized themselves with the rules of repair and installation works execution on vehicles and who have special professional knowledge in electronic and elect...

Страница 4: ...ystem with the tracker ADM333 BLE Immobilizer can be used as an electromechanical relay with switching group of contact elements or as a two channel output with overcurrent protection Can be installed...

Страница 5: ...semiconductor switches 40 V Maximum commuted current of semiconductor switches 0 9 A Maximum voltage between GND and NO outlets Output 1 40 V Maximum voltage between GND and N outlets Output 2 40 V Ma...

Страница 6: ...e than 15 V only semiconductor switches can be used and the use of electromechanical relay is prohibited The outlets of semiconductor switches and electromechanical relay are combined that is why thei...

Страница 7: ...housings and other plastic structures There is Antenna marking on the immobilizer sticker label the position of such marking coincides with the position of the antenna of Bluetooth LE radio interface...

Страница 8: ...he immobilizer switches only the minus of power supply load The plus of the power supply load should be connected from any appropriate section of power supply network The function of the outlets in th...

Страница 9: ...let NC or to the outlet NO When the voltage is not supplied to the electromechanical relay coil as well as to the immobilizer then outlet NC is closed to the outlet COM Functions of the outlets in ele...

Страница 10: ...and the tracker ADM333 BLE hereinafter referred as tracker is performed by sending commands to the tracker via Bluetooth GPRS and SMS 4 2 1 Connection of immobilizer to the tracker BLEOUTADDR command...

Страница 11: ...tting immobilizer ADM33 Use BLEOUTCFG command to set the immobilizer ADM33 stops Bluetooth environment scanning process and starts broadcasting Advertising messages To configure settings and select im...

Страница 12: ...ic UART Service There will appear the following menu 11 Field RX Characteristic will be used for settings and commands sending Field TX Characteristic will be used to display responses Next to the fie...

Страница 13: ...abet characters are used in commands Lower case characters Commands are separated by SPACE Parameters are set using Latin letters and Arabic numerals Having received a command the immobilizer performs...

Страница 14: ...nnection with the tracker is lost ts command is used 17 frequency of control messages receipt from the tracker in the status of immobilizer setting ad command is used 18 time of signal waiting from th...

Страница 15: ...arameters Save settings 6 cp X cp X password Consists only of Arabic numerals Password change 7 r X cr X operation mode 0 electromechanical relay 1 semiconductor switch only output 1 2 semiconductor s...

Страница 16: ...tion is considered to be lost 12 ad X ad time in seconds Waiting time when immobilizer is waiting to be connected to the tracker 13 ri ri X 0 inversion is switched off X 1 inversion of electromechanic...

Страница 17: ...lizer with mechanical damages and defects cracks and chips dents signs of impacts etc caused by consumer as a result of handling storage and transportation rules violation When there are signs of oxid...

Страница 18: ...33 Passport 11 Acceptance certificate Wireless sensors immobilizers ADM33 operation manual No 464512 004 in quantity of _____ pcs are considered to be ready for operation Date of manufacture Manufactu...