2.3-2 DMX512 ADDRESSING WITH ID ADDRESS (TOUR MODE)
Connect the DMX512 controller to the units in series
Each unit has 10 DMX channels so the DMX Addresses should increase by
increments of 13 (e.g. 1,14,27...)
Each DMX Address may be used as many times as required.
Any DMX address in the range from 001 to 512 may be used.
Each DMX address may carry up to 66 separate ID addresses.
ID
should be set in the menu on each unit in ascending values
(i.e. 1,2,3...)
ID On
should be set in the
Settings
menu on each unit.
ID addresses are accessible from Ch12 on the DMX512 controller.
TOUR
Note: This product have three DMX512 channel configuration:
TOUR , BLOCK1 ,
, ARC 1 , ARC 1+D ,
2 ,
2
and
HSV
BLOCK2
ARC
ARC +D
4.1 BASIC ADDRESSING
Connect all of the units in series using standard DMX512 signal cable or
the IP65 rated cable provided.
Set the DMX512 address in the
DMX
menu.
It is possible to have the same DMX address or independent
addresses for each fixture.
4.2 CHANNEL ASSIGNMENT
4 USING A DMX512 CONTROLLER
1
2
3
4
C O LO R M AC RO + W HITE BALANC E
5
6
BLUE
MASTER D IMMER
RED
G REEN
VALUE
FUNCTION
WHITE
AMBER
CHANNEL
Example:
DMX Addr.1
ID Addr.1
DMX Addr.1
ID Addr.2
DMX Addr.1
ID Addr.3
DMX Addr.14
ID Addr.1
DMX Addr.14
ID Addr.2
DMX Addr.14
ID Addr.3
DMX512
CONTROLLER
The figure above shows a simple DMX layout
which has used three units at each DMX address.
The three units have different ID addresses which
allows the user to collectively control the whole
group of units at that DMX address by setting
CH12 to 0, or to control each unit independently by
first selecting the DMX address and then by using
Ch12 to locate the target ID address.
............
7