background image

MENU

3.4 AUTO PLAY MODE

3.7 PERSONALITY

AUTO PLAY MODE

 Select the target

Auto

 program .

 Programs

AUTO 01

to

AUTO 10

are fully pre-programmed and will not be 

    altered by changes in

EDIT CUSTOM

mode.  The auto speed can be set from

SP 1~255 .

 Programs 

CUSTOM 01

to

CUSTOM10

are fully pre-programmed and can

     be edited in

EDIT CUSTOM

mode.

3.5 DMX ADDRESS

DMX ADDRESS

 Enter the

DMX ADDRESS

mode to set the DMX ADDRESS.

RUN MODE

 Enter the

RUN MODE

mode to set working mode.

DMX

 mode is for using the DMX512 controller to control the fixtures.

SLAVE

 mode is for Master -- Slave operation, or controlled fixture by 

    Pix-controller.

Note:

 When fixtures are under Auto program operation, the

RUN MODE

 does

           no  works.

3.6

    RUN MODE

PERSONALITY

 Enter the

PERSONALITY

mode to select DMX mode:

,

 

,

,

,

,

,

,

or 

.

3.8 ID ADDRESS

3.9 SPECIAL SETTINGS

SETTINGS

UPLOAD

 PASSWORD

RESET

 PASSWORD

ID ONOFF

OFF

ON

****

SEND...

END

****

RESET...

DIMMER

DIM1

OFF

DIM3

DIM2

DIM4

COLOR

RGB TO W

OFF

UC

MENU

ID ADDRESS

 Enter the

ID ADDRESS

mode to set the ID ADDRESS.

SETTING

 Enter

ID

in order to allow/disallow ID address function from the DMX512 

   controller.

 Select

UPLD

to upload the custom programs from the current MASTER unit to 

    the SLAVE units.

 In order to activate the upload function the password must be entered.

 Password is the same as the main access password.

 When uploading the MASTER and SLAVE units will display YELLOW.

 If an error occurs when uploading the MASTER and/or SLAVE units will display RED.

 On successful uploading of the custom programs the MASTER and SLAVE units 

    will display GREEN.

 In order to reset custom modes to default values select 

REST

.

 Enter 

Dim

 to select dimmer mode and dimmer speed. When DIMMER is

     set to 

Off

,  then RGBW and MASTER DIMMER are  linear. The Dim 1/2/3/4 

     are speed  modes of the non linear dimmer ,

Dim1

 is the faster, while 

Dim4

 is the slowest.

     The factory default setting is

Dim4 .

COLOR

 is for activate/unactivate the color calibration functions.

    When 

RGBW

is selected, on RGB = 255,255,255,  the color is displayed as 

     calibrated  in CAL2 -- RGBW.  When

COLOR

 is set 

OFF

,  on  RGB = 255,255,

   255,  the  RGB  values are not adjusted  and the  output is most powerful. 

    When [

UC

] is selected, the RGB output are adjusted to a standard preset universal color

    which balances fixtures from different generations..

ADDERSS

1~512

MENU

RUN

SLAVE

DMX

MENU

PERSON

TOUR
BLOCK1
BLOCK2
ARC 1
ARC 1+D
ARC 2
ARC 2+D
ARC 2+S
HSV

MENU

ID

 1~66

MENU

AUTO

AUTO 01

AUTO 10

CUSTOM 01
CUSTOM 02
CUSTOM 03
CUSTOM 04
CUSTOM 05
CUSTOM 06
CUSTOM 07

CUSTOM 08
CUSTOM 09
CUSTOM 10

SP

0~255

Содержание Sion

Страница 1: ...board Power supply Display PCB Fan Side cover LED driver PCB Fuse Supporting bracket No ITEM Power output socket white Power output socket blue 11 12 13 14 No ITEM 5 2 MAINTENANCE USER MANUAL Please...

Страница 2: ...PRODUCT GENERAL 1 1 1 PRODUCT INTRODUCTION 1 1 2 PRODUCT FEATURES 1 1 3 TECHNICAL SPECIFICATIONS 2 1 4 PHOTOMETRIC DATA 3 1 5 SAFETY WARNING 4 PART 2 INSTALLATION 5 2 1 MOUNTING 5 2 2 POWER CONNECTIO...

Страница 3: ...the slider is at the highest position 255 the intensity of the color is the maximum CH2 CH3 Ch4 Ch5 CH6can be combined together to create over 16 million colors COLOR MACROS AND WHITE BALANCE CH7 sele...

Страница 4: ...9 x AMBER Weight LED Unit Cooling 990 x 156 x75mm 6Kg 100 240V 50 60Hz 87W Environment Temperature 20 40 Forced air convection 1 2 0 255 3 0 255 0 255 HSV HUE SATURATION VALUE CHANNEL VALUE FUNCTION...

Страница 5: ...NNEL 1 2 3 0 1 2 3 2 4 6 8 10Distance m 1316 329 146 82 53 LUX 1 5 R 1 2 3 0 1 2 3 2 4 6 8 10Distance m 600 150 67 38 24 LUX A 1 5 1 2 3 0 1 2 3 2 4 6 8 10Distance m 3402 850 378 213 136 LUX RGBW 1 5...

Страница 6: ...s described in this user manual Avoid shaking or strong impacts to any part of the equipment Make sure that all parts of the equipment are kept clean and free of dust Always make sure that the power c...

Страница 7: ...with a clamp or other mounting bracket is recommended depending on the requirements of your application For overhead use always install two secure chains that can hold at least 10 times the weight of...

Страница 8: ...y DMX address in the range from 001 to 512 may be used Example DMX Addr 1 DMX Addr 14 DMX Addr 27 0 255 AUTO SPEED 10 AUTO SPEED FOR Auto1 Auto10 Auto 6 Auto 7 Auto 8 Auto 9 111 120 Auto 10 121 130 13...

Страница 9: ...l of the units in series using standard DMX512 signal cable or the IP65 rated cable provided Set the DMX512 address in the DMX menu It is possible to have the same DMX address or independent addresses...

Страница 10: ...e of the current function scroll through the mainmenu or return tothe main menu MENU ENTER 3 1 BASIC 3 DISPLAY PANEL OPERATION 3 13 FAN SETTING FAN SETTING Enter the FAN SETTING to select the fan spee...

Страница 11: ...4 5 7 8 9 DMX address 001 ID ON OFF ON COLOR OFF KEYLOCK OFF Parsonaliey TOUR Run mode DMX 10 Fan Auto 1 STATIC 000 ID address 001 6 DIMMER DIM4 EDIT 000 11 WHITE1 WHITE2 WHITE3 WHITE4 WHITE5 WHITE6 W...

Страница 12: ...unit to the SLAVE units In order to activate the upload function the password must be entered Password is the same as the main access password When uploading the MASTER and SLAVE units will display Y...

Отзывы: