background image

 

HEAD OFFICE 

Tel: +27 (0)11 462 8283 

 

Northriding Commercial Park 

Fax: +27 (0)11 462 7132 

 

Stand 251, Aintree Street, Northriding 
Randburg, South Africa 

EXPORTS 

Tel: +27 (0)11 462 8283 

 

[email protected] 

Fax: +27 (0)11 462 7132 

 

 

 

EDENVALE 

Tel: +27 (0)11 453 1970  

 

Unit 4, Meadowdale Park 

Fax: +27 (0)11 453 1858 

 

Cnr. Dick Kemp & Herman Roads 
Meadowdale, Edenvale, South Africa 

CAPE TOWN 

Tel: +27 (0)21 386-3742 

 

27B Concord Crescent, Airport City 

Fax: +27 (0)21 386-5573 

 

Cape Town, South Africa 

 

NELSPRUIT 

Tel: +27 (0)13 752-2187 

 

Waterval Ave, Riverside Industrial 

Fax: +27 (0)13 752-2188 

 

Nelspruit, South Africa 

 

KWAZULU-NATAL 

Tel: +27 (0)31 701-2125 

 

19 Henwood Road 

Fax: +27 (0)31 701-2125 

 

Pinetown, South Africa 

 

AUSTRALIA 

Tel: (08) 9303 9855   

 

Unit 5, 19 Innovation Circuit, 

Email: 

[email protected]

 

Wangara, 6065, Perth, WA, Australia 

 
 

Website: www.nemtek.com 

E-mail: [email protected] 

Manufactured in South Africa 

NEMTEK Group outlets 

Содержание druid LCD

Страница 1: ...Druid LCD Electric Fence Energizer Installer Manual ...

Страница 2: ...iguration 9 Fence wiring diagrams 10 Bi polar fence wiring diagrams 11 4 zone installation 12 Network card and Nemtek Connect 13 Large network 14 Detailed service indicators Fuses 15 Installation notes 16 Programmable options 17 Appendix 28 Programmable options summary 31 IEC Safety Information 32 Document revision history 32 Table of Contents 2 ...

Страница 3: ...hazards See APPENDIX at the end of this manual and warn the user to avoid head contact with the fence DISCLAIMER NEMTEK Holdings Pty Ltd or any of its subsidiary companies does not guarantee that the operation of the product will be uninterrupted or totally error free Energizer specifications may be altered without prior notification The installer is referred to the definitions and general require...

Страница 4: ...K Group outlets The buyer shall pay all shipping and other charges for the return of the product to NEMTEK or NEMTEK Security Warehouse LIMITATION OF GUARANTEE The guarantee does not apply to defects resulting from acts of God modifications made by the buyer or any third party misuse neglect abuse accident and mishandling EXCLUSIVE REMEDIES The remedies provided herein are NEMTEK s sole liability ...

Страница 5: ...h Africa CAPE TOWN Tel 27 0 21 386 3742 27B Concord Crescent Airport City Fax 27 0 21 386 5573 Cape Town South Africa NELSPRUIT Tel 27 0 13 752 2187 Waterval Ave Riverside Industrial Fax 27 0 13 752 2188 Nelspruit South Africa KWAZULU NATAL Tel 27 0 31 701 2125 19 Henwood Road Fax 27 0 31 701 2125 Pinetown South Africa AUSTRALIA Tel 08 9303 9855 Unit 5 19 Innovation Circuit Email nemtek bigpond ne...

Страница 6: ...gizer s state at a glance and from a distance The DRUID LCD energizer incorporates an advanced and patented fence voltage regulation arc detection and avoidance system What this means is the fence energy is maintained at a higher level than would normally be possible using a conventional energizer on the same fence when factors such as poor or damaged insulators wet insulators after a rain storm o...

Страница 7: ... slightly more than the thickness of the casing between screw heads and wall Position the casing so that the screws go through the slots provided then drop it into position Tighten the top 2 screws to secure the casing The bottom two screws will slot into the casing for stability they don t need to be tightened STEP 5 Insert battery with the negative terminal to the top STEP 6 Place the battery br...

Страница 8: ...r spade connectors beneath the PC Board in the middle of the board and two box connectors beneath and near the bottom of the board STEP 5 To replace the PC Board first align the box connector near the bottom of the PC Board and then align the four spade connectors at the top of the PC Board using the guide tabs and gently press the PCB down into place STEP 6 Re insert and tighten the five screws S...

Страница 9: ...rnal On Off Switch for Zone 1 External On Off Switch for Zone 2 Panic Switch Normally closed High Low voltage switch for Zone 1 High Low voltage switch for Zone 2 A maximum of two Nemtek Druid 4 Zone keypads two expansion cards and 100m of comms cable can be connected A total of two energizers can be linked together See Creating a 4 zone installation later on in this manual ...

Страница 10: ...e and not directly to the energizer All earth spikes are connected to one wire of the fence only and this one wire is connected to the rest of the fence at the main Earth wire connection with earth loop monitoring preferred The fence earth wire is to be connected to the main earth spike and not directly to the energizer Install the main earth spikes close to the energizer Earth wire connection wit...

Страница 11: ...Bi polar fence wiring diagrams 11 Live wire connection with double the voltage between adjacent strands Fence 1 Fence 2 Earth wire connection with no earth loop monitoring ...

Страница 12: ... as zones 1 2 on the keypad Slave will show as zones 3 4 on the keypad Lastly the master needs to be informed whether a slave energizer is connected creating a four zone system or if it is a master only two zone system This is so that a communication failure service alarm can be generated should the slave energizer not respond to the master s request for information and so that the keypad can be d...

Страница 13: ...ork card or a Nemtek Connect card can be connected These cards enable networking or remote access and control of the energiser Visit the Nemtek website www nemtek co za for the latest details on the smartphone app and networking options available to you Network cards and Nemtek Connect 13 ...

Страница 14: ...case for safety the energizers should be synchronised with one another Synchronisation is achieved by either making all energizers dependant on the timing of one of the energizers in the network or by making all energizers dependant on an accurate external clock source with a period of one second such as the GPS receiver available from Nemtek Use the installer code 503 detailed on page 26 of this ...

Страница 15: ...e or rapid triggering B Battery fuse blown battery fault or not connected N Slave energizer communication failure V Output high voltage sense error F High voltage boost circuit control loss FUSE DESCRIPTION AND FAULT SYMPTOMS All fuses are of the fast blow type with a 2A rating Main fuse 4A Detailed service indicators fuses 15 Main Fuse Energizer displays a battery symbol and not the mains power s...

Страница 16: ...gizer set to master Use HT high voltage wire between the fence and energizer including the earth wire Never run these wires in the same conduit or through the same hole as the low voltage wiring Always use ferrules or line clamps to connect two high voltage wires together Avoid using dissimilar materials for connections like copper on steel The fence must be earthed properly with three earth elect...

Страница 17: ...t code CHANGE INSTALLER PIN 0 0 _ _ _ _ _ _ Changes the factory default six digit installer PIN to a new six digit PIN SIREN ON TIME 0 1 _ _ Sets the siren on active time m minutes s x10 seconds Programmable range is 0101 10s to 0141 4m 10s Factory default value is 0120 2m 0s Siren active time is the amount of time that the siren will sound before automatically turning off if not reset by the user...

Страница 18: ...ed by law to prevent an alarm from sounding indefinitely while the owner is not home to correct the alarm condition RELAYS ACTIVE OPEN 0 0 6 _ Set the active state of all three relays on the energizer PCB 0 relay closed when active or 1 relay open when active Factory default value is 0060 relay normally open closed on activation Typically used when the energizer is connected to an alarm system req...

Страница 19: ...alarm sensor mode When this mode is active the display will indicate AlmSensr 0 conventional energizer mode or 1 alarm sensor mode Factory default value is 4080 conventional energizer mode When in alarm sensor mode the strobe relays regardless of STROBE LIGHT Z1 Z2 RELAY FUNCTION settings will function as follows The Zone 1 strobe relay is active only as long as zone 1 is in alarm condition The Zo...

Страница 20: ...ATE CHIME user code as detailed in the Druid LCD User Manual This GATE CHIME ON CLOSE installer code additionally enables chiming on closure of the gate as well INPUT TOGGLE SELECT 1 1 1 _ Selects toggling or direct on off control of the fence 0 direct control or 1 toggle control Factory default value is 1110 direct control With direct control the fence is energized when the input transitions to o...

Страница 21: ...fault value is 2030 disabled for DRUID_114 Fence interference may occur when a neighboring fence comes into contact with the fence been driven by this energizer or when criminals attempt to defeat the energizer fence alarm detection mechanism Can be directed to a specific zone using KEYPAD ZONE FOCUS FENCE HIGH POWER VOLTAGE 2 1 _ _ Sets the energizer output voltage during high power operation k k...

Страница 22: ...olts Programmable range is 2320 2 0kV to 2350 5 0kV Factory default value is 2330 3 0kV The alarm level must always be set below the check level for the new setting to be accepted Can be directed to a specific zone using KEYPAD ZONE FOCUS FENCE ALARM DELAY 2 5 _ _ Sets the number of violating fence pulses that have to occur before the alarm is activated number of pulses before alarm occurs Program...

Страница 23: ...CE HIGH POWER VOLTAGE to a value greater than 8kV will not raise the output voltage beyond 8kV when using conventional control For more information on arc detection and avoidance control read the FOREWORD at the front of this manual Can be directed to a specific zone using KEYPAD ZONE FOCUS MAGNETIC SWITCH 4 0 1 _ Enables or disables the magnetic switch 0 disabled or 1 enabled Factory default valu...

Страница 24: ...ty when the energizer and keypad are far apart it may be desirable to disable this function and so prevent the user PIN being read from the energizer display SOLAR POWERED INSTALLATION 4 0 7 _ Modifies the energizer operation for permanent battery operation 0 disabled requires mains power or 1 solar installation Factory default value is 4070 disabled If the energizer is to be run permanently from ...

Страница 25: ...one 1 On Off status Relay 7 Battery low or Service alarm Relay 3 Zone 2 On Off status Relay 8 Zone 1 in Check Relay 4 Zone 1 in low voltage mode Relay 9 Zone 2 in Check Relay 5 Zone 2 in low voltage mode Relay10 Energizer tamper state Input 1 Zone 1 On Off control Input 3 Zone 1 Low High voltage select Input 2 Zone 2 On Off control Input 4 Zone 2 Low High voltage select Configuration 1 Relay 1 Exp...

Страница 26: ...time from the network of satellites making up the global position system GPS The advantage of using a Nemtek GPS sync module is that any number of D24 energizers can be synchronized over vast distances without any physical network connections between the energizers To create a network of synchronized energizers using one of the energizers as the timing master first enter this code into all energiz...

Страница 27: ...nergizer to be found on a new network but for the network to operate correctly the energizer must finally be assigned an address in the range of 1 to 32 SET INSTALLER TEL NUMBER _ _ _ _ _ _ _ _ _ _ Sets the telephone number to be displayed during a service condition The telephone number must be exactly 10 digits long and the displaying of this number must be enabled as the factory default is to no...

Страница 28: ... General requirements for electric security fences Electric fences shall be installed and operated so that they cause no electrical hazard to persons animals or their surroundings Electric fence constructions which are likely to lead to the entanglement of animals or persons shall be avoided as entrapment can be lethal An electric fence shall not be supplied from two different energizers or from i...

Страница 29: ...pened without the person receiving an electric shock Connecting leads that are run inside buildings shall be effectively insulated from the earthed structural parts of the building This may be achieved by using insulated high voltage cable Connecting leads that are run underground shall be run in a conduit of insulating material or else insulated high voltage cable shall be used Care shall be take...

Страница 30: ...d reduces the risk of persons receiving an electric shock unless they attempt to penetrate the physical barrier or are in a secure area without authority Exposed conductive parts of the physical barrier shall be effectively earthed A spacing of 2 5m shall be maintained between non insulated electric fence conductors or non insulated connecting leads supplied from different energizers This spacing ...

Страница 31: ...NTERFERENCE ALARM 2 0 3 FENCE HIGH POWER VOLTAGE 2 1 k v FENCE HIGH POWER CHECK LEVEL 2 2 k v FENCE HIGH POWER ALARM LEVEL 2 3 k v FENCE ALARM DELAY 2 5 m s FENCE LOW POWER VOLTAGE 2 7 k v FENCE LOW POWER ALARM LEVEL 2 8 k v FENCE CONTROL ALGORITHM 3 0 1 MAGNETIC SWITCH 4 0 1 TAMPER ALARM 4 0 3 SERVICE ALARM 4 0 4 DISPLAY INSTALLER TEL NUMBER 4 0 5 SHOW KEY PRESSES ON LCD 4 0 6 SOLAR POWERED INSTA...

Страница 32: ...iven supervision or instruction concerning use of the appliance by a person responsible for their safety Electric fencing can be lethal Avoid head contact with the fence Ask the installer to explain the options of current limiting resistors the programmable output energy levels as well as the low voltage operation of the energizer Rev 1 0 1 May 2012 First release Rev 1 1 11 June 2012 Added more ex...

Отзывы: