FENCE LOW POWER ALARM LEVEL
2 8 _ _ * #
Sets the value at which the BAD message will be displayed, and the alarm will sound
should the fence return voltage reduce to or below this set value when operating in low
power mode.
k = kilo volts, v = x100 volts
Programmable range is
2805*#
(0.5kV) to
2815*#
(1.5kV)
Factory default value is
2808*#
(0.8kV)
*Can be directed to a specific zone, using KEYPAD ZONE FOCUS.
FENCE CONTROL ALGORITHM
3 0 1 _ * #
Sets the fence control algorithm.
? = 0 (conventional) or 1 (arc detection and avoidance)
Factory default value is
3011*#
(arc detection and avoidance)
Conventional control will output a maximum of 8kV onto the fence to reduce the risk of arcing
across insulators. Setting the FENCE HIGH POWER VOLTAGE to a value greater than 8kV will not
raise the output voltage beyond 8kV when using conventional control. For more information on arc
detection and avoidance control, read the FOREWORD at the front of this manual.
*Can be directed to a specific zone, using KEYPAD ZONE FOCUS.
MAGNETIC SWITCH
4 0 1 _ * #
Enables or disables the magnetic switch.
? = 0 (disabled) or 1 (enabled)
Factory default value is
4011*#
(enabled)
When using a keypad, disable the magnetic switch to increase the level of security offered.
TAMPER ALARM
4 0 3 _ * #
Enables or disables the tamper alarm function.
? = 0 (disabled) or 1 (enabled)
Factory default value is
4031*#
(enabled)
When enabled, the tamper alarm will sound if the energizer front is opened while the fence is
energized. The tamper symbol t will always be shown on the display, regardless of whether the
tamper alarm is enabled or disabled.
Programmable options
23