Symbol interpretation 

 

Fence or Gate alarm condition present:

 

 

Fence or Gate alarm history (occurred in the past): 

Fence or Gate alarm bypassed: 

 

Gate is open: 

Gate alarm immediate (alarm will sound the moment the gate is opened): 

 

Mains power present: 

Mains fail history (occurred in the past): 

Mains power fail with internal battery condition 

GOOD

:      , 

LOW

:       or 

FLAT

 

Energizer requires servicing (if displayed for an extended period): 

Energizer possibly tampered with (front cover is, or was opened): 

Energizer set to silent alarm (no external siren or strobe will activate): 

 

Fence set to low power:  

Fence voltage is below CHECK threshold: 

Fence voltage is below ALARM threshold: 

Fence is off: 

Fence condition indication from 

0

 to 

9

 (higher values are better) 

 

Fence condition and voltage notes 

 
Fence voltage 

CHECK

 and 

BAD

 (alarm) thresholds are installer settable values. 

 
The fence condition indication should be maintained at a high value for maximum fence 
effectiveness. This is achieved through regular maintenance of the fence, cutting back and 
removal of foliage from off the fence, removal of dead slugs, snails, spiders and other 
insects from off of insulators, and replacing any insulators that may have failed. 
 
Druid LCD 2x Energizers, when set up to run with and external sync signal, will display 

S S

 

in the fence condition positions when the sync signal is lost. 

lo 


Содержание druid LCD

Страница 1: ...Druid LCD Electric Fence Energizer User Manual...

Страница 2: ...K Group outlets 5 Foreword 6 Symbol interpretation 7 Symbol to label link 8 Operation without a keypad 9 Operation with a keypad 10 Using your keypad 11 Keypad zone focus 16 IEC Safety Information 17...

Страница 3: ...eneral information are available on our web site at http www nemtek com COMPANY PROFILE The NEMTEK Group of Companies manufacture and distribute intelligent electronic agricultural fencing systems sec...

Страница 4: ...Group outlets The buyer shall pay all shipping and other charges for the return of the product to NEMTEK or NEMTEK Security Warehouse LIMITATION OF GUARANTEE The guarantee does not apply to defects r...

Страница 5: ...Africa CAPE TOWN Tel 27 0 21 386 3742 27B Concord Crescent Airport City Fax 27 0 21 386 5573 Cape Town South Africa NELSPRUIT Tel 27 0 13 752 2187 Waterval Ave Riverside Industrial Fax 27 0 13 752 21...

Страница 6: ...gizer incorporates an advanced and patented fence voltage regulation arc detection and avoidance system What this means is that the fence energy is maintained at a higher level than would normally be...

Страница 7: ...ence voltage is below CHECK threshold Fence voltage is below ALARM threshold Fence is off Fence condition indication from 0 to 9 higher values are better Fence condition and voltage notes Fence voltag...

Страница 8: ...he display under the third linking line the symbol is linked to the FENCE MODE label and is interpreted to mean that the fence is off If however the O symbol is positioned on the right of the display...

Страница 9: ...he unit An initial short beep will be heard as the tab is detected but keep holding the tab in place until a second longer beep is heard The siren will be silenced if not yet timed out the internal be...

Страница 10: ...user is referred to as user number 2 or PIN 2 Most energizer user functions are accessed using the master PIN followed by a key a two key sequence and then completed with the enter key The two key seq...

Страница 11: ...tion and fence voltage Acknowledging and silencing an alarm condition _ _ _ _ Enter the reset PIN default reset PIN is 5555 The siren will be silenced if not yet timed out the internal beeper will sto...

Страница 12: ...ence low power voltage is an installer programmable voltage If the fence is in low power the symbol under the FENCE label on the keypad will be lit and on the energizer display the symbol linked to th...

Страница 13: ...gate is opened without waiting for the gate delay time to expire If the gate alarm is instant the i symbol under the GATE label on the keypad will be lit and on the energizer display the i symbol lin...

Страница 14: ...PIN is required CHANGING A USER PIN _ _ _ _ 0 start change user PIN _ _ _ _ enter new PIN _ _ _ _ confirm new PIN To change a user PIN requires three key code sequences in succession Depending on whic...

Страница 15: ...the harder the energizer has to work to maintain the voltage on the fence This is reflected as an increase in stored energy and energizer capacity used The energizer cannot work harder than 100 effort...

Страница 16: ...rolling both zone 3 and zone 4 To change the keypads focus to all zones so that keypad activity is directed to both energizers and so that all four zones respond type 0 into the keypad While in global...

Страница 17: ...instruction concerning use of the appliance by a person responsible for their safety Electric fencing can be lethal Avoid head contact with the fence Ask the installer to explain the options of curren...

Отзывы: