DISPLAY INFORMATION
6 ? #
Replace the
?
above with the required digit for the information you want displayed as
listed below.
•
GOOD, CHECK, BAD
6 0 #
This is the default display as shipped from the factory and shows the words
GOOD
,
CHECK
or
BAD
dependent upon the fence voltage and fence condition.
•
V-PEAK OUT, V-PEAK RETURN
6 1 #
This display shows the energizer output (
o
) and return (
r
) terminal voltages in kilo volts
(
kV
)
•
STORED ENERGY, CAPACITY USED
6 2 #
This display shows the stored energy in joules (
j
) and the energizer effort or capacity used
as a percentage (
%
). The larger the fence installation or the greater the loading on the
fence, the harder the energizer has to work to maintain the voltage on the fence. This is
reflected as an increase in stored energy and energizer capacity used. The energizer
cannot work harder than 100% effort.
•
FENCE VOLTAGE LOSS
6 3 #
This display shows the voltage drop, or loss as a percentage (
%
), across the fence from
beginning to end.
•
BATTERY VOLTAGE
6 4 #
This display shows the internal battery voltage level in volts (
V
).
No PIN is required for the Display Information code as no operating parameters are
altered.
OUT1 RELAY CONTROL
* 1 ? #
(DRUID 18 and 114A only)
Replace the ? above with a
1
to activate or a
0
to deactivate the
OUT1
relay manually.
This relay can be used as a keypad controlled switch. See ‘
OUT1 RELAY FUNCTION
’ in
the ‘
DRUID LCD 1xx Installer Manual
’ for more detail on configuring the
OUT1
relay
function.
Using your keypad
15