background image

INSTALLER INSTRUCTIONS

 
 

nekos

 products have been manufactured in accordance with safety standards and 

conforms to the stipulations of current standards in force. 
When correctly assembled, installed and used according to the present instructions, they 
will not generate any danger for persons, animals or items. 
 
 
 

Symbols used in the manual

 

 

DANGER 

 

Contents 

1.  SECURITY RULES................................
2.  TECHNICAL INFORMATION FOR APPLICATION AND OPERATION
3.  TECHNICAL DATA ................................
4.  CONSTRUCTION AND REGULATORY REFERENCES
5.  ID PLATE AND MARKING DATA
6.  ELECTRIC POWER SUPPLY
7.  SETTING THE DIP-SWITCHES 
8.  ASSEMBLY INSTRUCTIONS

8.1. Preparation of actuator for assembly
8.2. Installation ................................

8.2.1.  Milling of the seats for recessed assembly
8.2.2.  Recessed assembly
8.2.3.  Drilling for external assembly
8.2.4.  External assembly ................................

9.  ELECTRICAL CONNECTION
10. START-UP OPERATIONS  ................................

10.1.  With actuator  ................................
10.2.  Without actuator (test) ................................

11. MAINTENANCE OR CLEANING
12. EMERGENCY OPERATIONS OR MALFUNCTIONS

12.1.  Emergency operations ................................
12.2.  Malfunctions of the device
12.3.  LED Light signals ................................

13. ENVIRONMENTAL PROTECTION
14. CERTIFICATE OF GUARANTEE
15. DECLARATION OF INCORPORATION (for a partly completed machine) AND EC 

DECLARATION OF CONFORMITY

 

 

 

INSTALLER INSTRUCTIONS

 

products have been manufactured in accordance with safety standards and 

conforms to the stipulations of current standards in force.  
When correctly assembled, installed and used according to the present instructions, they 
will not generate any danger for persons, animals or items.  

Symbols used in the manual 

This indication draw the attention about potential dangers for 
health of peoples and animals. 

................................................................................................

TECHNICAL INFORMATION FOR APPLICATION AND OPERATION

................................................................................................

CONSTRUCTION AND REGULATORY REFERENCES ................................
ID PLATE AND MARKING DATA ................................................................
ELECTRIC POWER SUPPLY ................................................................

SWITCHES – Selecting the stroke and setting the operating mode

ASSEMBLY INSTRUCTIONS ................................................................

Preparation of actuator for assembly ................................................................

................................................................................................

Milling of the seats for recessed assembly ................................
Recessed assembly ................................................................
Drilling for external assembly ................................................................

................................................................................................

ELECTRICAL CONNECTION ................................................................

................................................................................................

................................................................................................

................................................................................................

MAINTENANCE OR CLEANING ................................................................
EMERGENCY OPERATIONS OR MALFUNCTIONS................................

................................................................................................

Malfunctions of the device ................................................................

................................................................................................

ENVIRONMENTAL PROTECTION ................................................................
CERTIFICATE OF GUARANTEE ................................................................
DECLARATION OF INCORPORATION (for a partly completed machine) AND EC 

DECLARATION OF CONFORMITY ................................................................

INSTALLER INSTRUCTIONS 

products have been manufactured in accordance with safety standards and 

When correctly assembled, installed and used according to the present instructions, they 

This indication draw the attention about potential dangers for safety and 

.................................................... 4 

TECHNICAL INFORMATION FOR APPLICATION AND OPERATION ..................................... 5 

.................................................... 5 

.......................................................... 5 

.............................................................. 6 

................................................................... 7 

Selecting the stroke and setting the operating mode .......... 7 

................................................................... 8 

................................................... 8 

............................................................ 9 

................................................................. 9 

.................................................................... 9 

.................................................... 10 

..................................... 10 

................................................................. 10 

..................................... 11 

.................................................. 11 

..................................... 12 

............................................................. 12 

.............................................................. 12 

.................................... 12 

............................................................... 12 

............................................ 13 

......................................................... 14 

............................................................ 14 

DECLARATION OF INCORPORATION (for a partly completed machine) AND EC 

...................................................... 15 

1. SECURITY RULES 

 

C

AREFULLY  OBSERVE  ALL

PERSONAL SAFETY

.

 

I

MPROPER INSTALLATION

 

MANDATORY RISK ANALY

The  Nekos  electrical  actuators comply  with the  Machinery  Directive  (2006/42/EC), Standard 
IEC 60335-2-103 (Particular requirements for drives for gates, doors and windows) and other 
directives  and  regulations  indicated  in  the  attached  Declarations  of  Incor
Conformity  (at  the  end  of  the  manual).  According  to  the  Machinery  Directive,  actuators  are 
“partly  completed  machinery”  intended  for  incorporation  into  doors  and  windows.  The 
manufacturer/supplier  of  the  window  is  required,  with  exclusive  r
compliance  of the entire system  with  the  applicable standards  and  to issue CE  certification. 
We  strongly  discourage  any  use  of  the  actuators  other  than  that specified  and  therefore,  in 
any case, the supplier of the complete sys
For  systems  installed  at  a  height  of  less  than  2.5  m  above  floor  level  or  other  levels 

accessible  to  users,  the  manufacturer/supplier  of  the  window  must  conduct 
regarding potential harm (violent blows, crushing, w
or possible malfunction or accidental breakage of the automated windows, and to implement 
suitable protective measures in view of these. Such measures include those recommended 
by the specified standard: 

-  controlling the actuators via a “deadman’s button” placed near the system and within the 

operator’s field of view, to ensure that people are out of the  way during operation. The 
button  must  be  placed  at  a  height  of  1.5  m  and  operated  by  key  if  accessible  to  the 
public; or:  

-  use  of  contact  safety systems  (also  included  in  the  actuators) that  ensure  a  maximum 

closing force of 400/150/25 N, measured in accordance with paragraph BB.20.107.2 of 
IEC 60335-2-103; or: 

-  use of non-contact safety systems (lasers, light grids); or:
-  use of fixed safety barriers that prevent access to moving parts.

Automated windows are deemed adequately protected if they: 
- are installed at a height of >2.5 m; or:

 - have a leading-edge opening of <200 mm and a closing speed of <15 mm/s; or:

- are part of a smoke and heat evacuation system for emergency use only.
In  any  case,  moving  parts  of  windows  that  could  fall  below  2.5  m  following  breakage  of  a 
system  component  need  to  be  fixed  or 
falling or collapsing: e.g. the use of safety arms on bottom

 

The  device  is  not  intended  for  use  by  persons  (including  children)  with  reduced 
physical, sensory or mental capabilities, or lacking experience and knowledge. Do not 
allow children to play with the fixed controls and keep any remote
their reach. 
The  actuator  is  destined  exclusively  for  installation  indoors.  For  any  special 
application we recommend you consult the manufacturer beforehand.
After removing packaging, check f
Always  request  exclusive  use  of  original  spare  parts.  Failure  to  respect  this 
condition  could  compromise  safety  and  invalidate  the  benefits  contained  in  the 
warranty for the appliance.
In  the  event  of  any  problems  or  queries
manufacturer directly. 

AREFULLY  OBSERVE  ALL  THE  FOLLOWING  INSTALLATION  INSTRUCTIONS 

MPROPER INSTALLATION CAN SERIOUSLY ENDANG

MANDATORY RISK ANALYSIS AND PROTECTION MEASURES

The  Nekos  electrical actuators comply  with the  Machinery Directive (2006/42/EC), Standard 

103 (Particular requirements for drives for gates, doors and windows) and other 

directives  and  regulations  indicated  in  the  attached  Declarations  of  Incor
Conformity  (at  the  end  of  the  manual).  According  to  the  Machinery  Directive,  actuators  are 
“partly  completed  machinery”  intended  for  incorporation  into  doors  and  windows.  The 
manufacturer/supplier  of  the  window  is  required,  with  exclusive  responsibility,  to  ensure  the 
compliance  of the  entire system  with  the  applicable  standards  and to issue  CE  certification. 
We strongly  discourage  any  use  of  the  actuators  other  than  that  specified  and  therefore,  in 
any case, the supplier of the complete system retains full liability.  
For  systems  installed  at  a  height  of  less  than  2.5  m  above  floor  level  or  other  levels 

accessible  to  users,  the  manufacturer/supplier  of  the  window  must  conduct 
regarding potential harm (violent blows, crushing, wounds) caused to people by normal use 
or possible malfunction or accidental breakage of the automated windows, and to implement 

in view of these. Such measures include those recommended 

e actuators via a “deadman’s button” placed near the system and within the 

operator’s field of view, to ensure that people are out of the  way during operation. The 
button  must  be  placed  at  a  height  of  1.5  m  and  operated  by  key  if  accessible  to  the 

use  of  contact  safety systems  (also included  in  the  actuators)  that  ensure  a  maximum 
closing force of 400/150/25 N, measured in accordance with paragraph BB.20.107.2 of 

contact safety systems (lasers, light grids); or: 

use of fixed safety barriers that prevent access to moving parts. 

Automated windows are deemed adequately protected if they:  

are installed at a height of >2.5 m; or: 

edge opening of <200 mm and a closing speed of <15 mm/s; or:

rt of a smoke and heat evacuation system for emergency use only.

In  any  case,  moving  parts  of  windows  that  could  fall  below  2.5  m  following  breakage  of  a 
system  component  need  to  be  fixed  or  secured  in  order  to  prevent  them  from  suddenly 

: e.g. the use of safety arms on bottom-hung windows.

The  device  is  not  intended  for  use  by  persons  (including  children)  with  reduced 
physical, sensory or mental capabilities, or lacking experience and knowledge. Do not 

with the fixed controls and keep any remote

The  actuator  is  destined  exclusively  for  installation  indoors.  For  any  special 
application we recommend you consult the manufacturer beforehand.
After removing packaging, check for any damage on the appliance.
Always  request  exclusive  use  of  original  spare  parts.  Failure  to  respect  this 
condition  could  compromise  safety  and  invalidate  the  benefits  contained  in  the 
warranty for the appliance. 
In  the  event  of  any  problems  or  queries,  consult  your  agent  or  contact  the 

 

LATION  INSTRUCTIONS  TO  ENSURE 

CAN SERIOUSLY ENDANGER SAFETY

.

 

 

The  Nekos  electrical  actuators comply  with the  Machinery Directive (2006/42/EC), Standard 

103 (Particular requirements for drives for gates, doors and windows) and other 

directives  and  regulations  indicated  in  the  attached  Declarations  of  Incorporation  and  CE 
Conformity  (at  the  end  of  the  manual).  According  to  the  Machinery  Directive,  actuators  are 
“partly  completed  machinery”  intended  for  incorporation  into  doors  and  windows.  The 

esponsibility,  to  ensure  the 

compliance of the entire system  with  the  applicable  standards  and to issue  CE  certification. 
We  strongly  discourage  any  use  of  the  actuators  other  than  that  specified  and  therefore,  in 

For  systems  installed  at  a  height  of  less  than  2.5  m  above  floor  level  or  other  levels 

accessible  to  users,  the  manufacturer/supplier  of  the  window  must  conduct 

risk  analysis 

ounds) caused to people by normal use 

or possible malfunction or accidental breakage of the automated windows, and to implement 

in view of these. Such measures include those recommended 

e actuators via a “deadman’s button” placed near the system and within the 

operator’s field of view, to ensure that people are out of the  way during operation. The 
button  must  be  placed  at  a  height  of  1.5  m  and  operated  by  key  if  accessible  to  the 

use  of  contact  safety systems  (also included  in  the  actuators)  that  ensure  a  maximum 
closing force of 400/150/25 N, measured in accordance with paragraph BB.20.107.2 of 

edge opening of <200 mm and a closing speed of <15 mm/s; or: 

rt of a smoke and heat evacuation system for emergency use only. 

In  any  case,  moving  parts  of  windows  that  could  fall  below  2.5  m  following  breakage  of  a 

secured  in  order  to  prevent  them  from  suddenly 

hung windows. 

The  device  is  not  intended  for  use  by  persons  (including  children)  with  reduced 
physical, sensory or mental capabilities, or lacking experience and knowledge. Do not 

with the fixed controls and keep any remote-control units out of 

The  actuator  is  destined  exclusively  for  installation  indoors.  For  any  special 
application we recommend you consult the manufacturer beforehand. 

or any damage on the appliance. 

Always  request  exclusive  use  of  original  spare  parts.  Failure  to  respect  this 
condition  could  compromise  safety  and  invalidate  the  benefits  contained  in  the 

,  consult  your  agent  or  contact  the 

Содержание K-LOCK

Страница 1: ...tre authorised by the manufacturer Do not use if repair or adjustment is required CAUTION if the power cable is damaged it must be replaced by qualified personnel from a service centre authorised by t...

Страница 2: ...aging check f Always request exclusive use of original spare parts Failure to respect this condition could compromise safety and invalidate the benefits contained in the warranty for the appliance In...

Страница 3: ...box that contains One linear electric actuator having a stroke of 18 and 36 mm with a 2 m cable Package of small metal parts Instructions manual 5 ID PLATE AND MARKING DATA The K LOCK actuators have C...

Страница 4: ...tor This dip switch when placed in the OFF position the OPEN CLOSE hook occurs according to the polarity of the power supply between wire1 and wire2 wire1 24V CLOSE wire1 24V This mode is useful durin...

Страница 5: ...he window frame Make the electrical connections following the instructions and diagram provided below Complete the path of the Perform a final test and verify that the device operates correctly on the...

Страница 6: ...Lack of electricity to the power supply unit The power supply unit does not supply 24V 12 Supply power again and check operation of the assembly which must be as seen on Repeat the complete cycle a se...

Страница 7: ...E LED LED Status Meaning STEADY ON Duration 0 5 seconds Internal memory write process in progress STEADY ON RESET Procedure in progress FLASHING RESET Procedure finished correctly The number of flashe...

Страница 8: ...ettiva Compatibilit Elettromagnetica ElectroMagnetic Compatibility Directive EMCD 2014 35 EU Direttiva Bassa Tensione Low Voltage Directive LVD 2011 65 EU Direttiva sulla restrizione dell uso di deter...

Отзывы: