Operating the appliance       

en

9

Control panel model 2

Setting the fan

Switching on

Touch the 

#

 symbol.

The fan starts at setting 

ƒ

.

Touch + or - to alter the fan speed.

Switching off

Touch the 

#

 symbol.

Intensive setting

You can use the intensive setting if there is a large 

build-up of odours and fumes/vapours.

Switching on

Touch the 

˜

 symbol. 

˜ƒ

 will light up on the display. 

Touch the 

˜

 symbol again to switch back to intensive 

mode 

˜‚

.

Note: 

After approx. 6 minutes, the extractor hood 

automatically switches back to fan setting 3.

Switching off

If you want to end intensive mode before the preset 

time expires, touch the 

˜

 symbol.

Automatic mode

Switching on

1.

Touch the 

#

 symbol.

The fan will start at setting 

ƒ

.

2.

Touch the 

 symbol.

The optimum fan setting is set using an automatic air 

sensor.

Switching off

Touch the 

 or 

#

 symbol to switch off automatic mode.

The fan will switch itself off automatically if the 

automatic air sensor detects no further change in the air 

quality in the room.
Automatic mode can run for a maximum of 4 hours.

Fan run-on time

Switching on

Touch the 

A

 symbol while the fan is running at fan 

setting 1.
The fan will run at fan setting 1.
After approximately 10 minutes, the fan will switch itself 

off automatically.

Switching off

Touch the 

@

 symbol to select a different fan setting.

This immediately stops fan run-on.

AirFresh function

Switching on

Touch the 

3

 symbol.

3

 will be shown on the display panel.The fan runs for 

approximately 5 minutes per hour at fan setting 1.

Switching off

Touch the 

3

 symbol.

This ends the AirFresh function.

Symbol

Explanation

#

Fan on/off

Q

Noise reduction function

3

AirFresh function

A

Reduce fan setting/fan run-on

@

Increase fan settings/intensive mode 1, 2

˜

Intensive mode 2 shortcut

Automatic air sensor

6

Light on/off/dimming

Indicator/

symbol

Explanation

Q

Noise reduction function

1-3

Fan settings

9

Fan run-on

3

AirFresh function

Содержание D96BMU5N0A

Страница 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Страница 2: ......

Страница 3: ...ion This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer...

Страница 4: ...dows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest th...

Страница 5: ...Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a d...

Страница 6: ...onmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventil...

Страница 7: ...e is a large build up of odours and fumes vapours Switching on Touch the symbol will light up on the display Touch the symbol again to switch back to intensive mode Note After approx 6 minutes the ext...

Страница 8: ...ust be switched over accordingly The extractor hood must be connected and switched on Touch and hold the Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filters that ca...

Страница 9: ...e fan will switch itself off automatically if the automatic air sensor detects no further change in the air quality in the room Automatic mode can run for a maximum of 4 hours Fan run on time Switchin...

Страница 10: ...To do this touch the A symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be c...

Страница 11: ...nderneath with your other hand 2 Take the metal grease filter out of the holder Notes Fat may accumulate in the bottom of the metal grease filter Hold the metal grease filter level to prevent fat from...

Страница 12: ...e metal grease filter has not been inserted correctly open the lock and reinsert the metal grease filter correctly 3Trouble shooting TroubleshootingMalfunctions often have simple explanations Please r...

Страница 13: ...ance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the accessory E no FD no After sales serviceO G...

Страница 14: ...liance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least wi...

Страница 15: ...coming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does no...

Страница 16: ...egrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The permanent electrical installation must only...

Страница 17: ...ting pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure gr...

Страница 18: ...2 Use the enclosed template to mark the positions for the screws and the outline of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for fastening the appliance and press in t...

Страница 19: ...e air pipe connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appr...

Страница 20: ...9001359222 9001359222 980615 en...

Отзывы: