    Operating the appliance

10

Noise reduction function

The noise reduction function reduces the fan noise.

Switching on

Note: 

This function can be used at any fan setting 

except fan setting 

. The function will remain active 

even after the fan is switched off.

Touch the 

Q

 symbol.

Switching off

Touch the 

Q

 symbol.

Lighting

The lighting can be switched on and off independently 

of the fan.
Touch the 

6

 symbol.

Setting the brightness

Press and hold the 

6

 symbol until the required 

brightness is reached.

Saturation display

If the metal grease filters or the activated charcoal filter 

are/is saturated, the corresponding symbols flashes 

after the appliance is switched off:

Metal grease filter:

 

”ªª

Activated charcoal filter:

 

’ªª

Metal grease filter and activated charcoal filter:

 

”ªª

 and 

’ªª

If you have not yet done so, the metal grease filters 

should now be cleaned or the activated charcoal filter 

replaced. 

~

 "Cleaning and maintenance" on page 11

Note: 

The saturation indicator does not apply for non-

renewable activated charcoal filters that are inserted 

downstream of the metal grease filter. These activated 

charcoal filters must be replaced twice a year.

The saturation indicators can be reset while they are 

flashing. To do this, touch the 

A

 symbol.

Switching over the display for air recirculation mode

For air recirculation mode, the electronic controller must 

be switched over accordingly:

The extractor hood must be connected and switched 

on.

Touch and hold the 

Q

 symbol and touch the 

@

 or 

A

 symbol until "2" lights up for air recirculation mode 

(filters that cannot be regenerated). Take your finger 

off the 

Q

 symbol. This will switch the electronic 

controller over to air recirculation mode (filters that 

cannot be regenerated).

Touch and hold the 

Q

 symbol and touch the 

@

 or 

A

 symbol until "3" lights up for air recirculation mode 

(filters that can be regenerated). Take your finger off 

the 

Q

 symbol. This will switch the electronic 

controller over to air recirculation mode (filters that 

can be regenerated).

Repeatedly touching and holding the 

Q

 symbol and 

touching the 

@

 or 

A

 symbol until "1" lights up 

switches the electronic controller back over to air 

extraction mode.

Audible signal 

Switching on

Touch and hold the 

#

 and 

Q

 symbols at the same 

time for approximately 3 seconds when the fan is 

switched on. An audible signal will sound as an 

acknowledgement.
When the signal tone is activated, 

 will be lit.

Switching off

Touch and hold the 

#

 and 

Q

 symbols at the same 

time for approximately 3 seconds when the fan is 

switched on. An audible signal will sound as an 

acknowledgement.
When the signal tone is deactivated, 

 will be lit.

Содержание D96BMU5N0A

Страница 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Страница 2: ......

Страница 3: ...ion This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer...

Страница 4: ...dows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest th...

Страница 5: ...Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a d...

Страница 6: ...onmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventil...

Страница 7: ...e is a large build up of odours and fumes vapours Switching on Touch the symbol will light up on the display Touch the symbol again to switch back to intensive mode Note After approx 6 minutes the ext...

Страница 8: ...ust be switched over accordingly The extractor hood must be connected and switched on Touch and hold the Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filters that ca...

Страница 9: ...e fan will switch itself off automatically if the automatic air sensor detects no further change in the air quality in the room Automatic mode can run for a maximum of 4 hours Fan run on time Switchin...

Страница 10: ...To do this touch the A symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be c...

Страница 11: ...nderneath with your other hand 2 Take the metal grease filter out of the holder Notes Fat may accumulate in the bottom of the metal grease filter Hold the metal grease filter level to prevent fat from...

Страница 12: ...e metal grease filter has not been inserted correctly open the lock and reinsert the metal grease filter correctly 3Trouble shooting TroubleshootingMalfunctions often have simple explanations Please r...

Страница 13: ...ance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the accessory E no FD no After sales serviceO G...

Страница 14: ...liance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least wi...

Страница 15: ...coming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does no...

Страница 16: ...egrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The permanent electrical installation must only...

Страница 17: ...ting pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure gr...

Страница 18: ...2 Use the enclosed template to mark the positions for the screws and the outline of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for fastening the appliance and press in t...

Страница 19: ...e air pipe connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appr...

Страница 20: ...9001359222 9001359222 980615 en...

Отзывы: