background image

en

    Important safety information

16

:

Warning – Risk of electric shock! 

Components inside the appliance may have 

sharp edges. These may damage the 

connecting cable. Do not kink or pinch the 

connecting cable during installation.

Risk of electric shock! 

It must always be possible to disconnect 

the appliance from the electricity supply. 

The appliance must only be connected to a 

protective contact socket that has been 

correctly installed. 

The mains plug of the mains power cable 

must be easily accessible after installation 

of the appliance. If this is not possible, an 

all-pole isolating switch must be integrated 

into the permanent electrical installation 

according to the conditions of overvoltage 

category III and according to the installation 

regulations.

The permanent electrical installation must 

only be wired by a professional electrician. 

We recommend installing a residual-current 

circuit breaker (RCCB) in the appliance's 

power supply circuit.

:

Warning – Risk of electric shock! 

Incorrect repairs are dangerous. Repairs may 

only be carried out and damaged power 

cables replaced by one of our trained after-

sales technicians. If the appliance is defective, 

unplug the appliance from the mains or switch 

off the circuit breaker in the fuse box. Contact 

the after-sales service.

:

Warning – Danger of suffocation! 

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

Содержание D96BMU5N0A

Страница 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Страница 2: ......

Страница 3: ...ion This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer...

Страница 4: ...dows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest th...

Страница 5: ...Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a d...

Страница 6: ...onmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventil...

Страница 7: ...e is a large build up of odours and fumes vapours Switching on Touch the symbol will light up on the display Touch the symbol again to switch back to intensive mode Note After approx 6 minutes the ext...

Страница 8: ...ust be switched over accordingly The extractor hood must be connected and switched on Touch and hold the Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filters that ca...

Страница 9: ...e fan will switch itself off automatically if the automatic air sensor detects no further change in the air quality in the room Automatic mode can run for a maximum of 4 hours Fan run on time Switchin...

Страница 10: ...To do this touch the A symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be c...

Страница 11: ...nderneath with your other hand 2 Take the metal grease filter out of the holder Notes Fat may accumulate in the bottom of the metal grease filter Hold the metal grease filter level to prevent fat from...

Страница 12: ...e metal grease filter has not been inserted correctly open the lock and reinsert the metal grease filter correctly 3Trouble shooting TroubleshootingMalfunctions often have simple explanations Please r...

Страница 13: ...ance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the accessory E no FD no After sales serviceO G...

Страница 14: ...liance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least wi...

Страница 15: ...coming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does no...

Страница 16: ...egrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The permanent electrical installation must only...

Страница 17: ...ting pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure gr...

Страница 18: ...2 Use the enclosed template to mark the positions for the screws and the outline of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for fastening the appliance and press in t...

Страница 19: ...e air pipe connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appr...

Страница 20: ...9001359222 9001359222 980615 en...

Отзывы: