    Important safety information

4

(

Important safety 

information

Important safety information

:

Warning – Danger of suffocation! 

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

:

Warning – Danger of death! 

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room 

if the appliance is being operated in exhaust 

air mode at the same time as room air-

dependent heat-producing appliance is being 

operated.

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or 

water heaters) obtain combustion air from the 

room in which they are installed and discharge 

the exhaust gases into the open air through an 

exhaust gas system (e.g. a chimney).

In combination with an activated vapour 

extractor hood, room air is extracted from the 

kitchen and neighbouring rooms - a partial 

vacuum is produced if not enough fresh air is 

supplied. Toxic gases from the chimney or the 

extraction shaft are sucked back into the living 

space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning – Risk of fire! 

Fatty deposits in the grease filter may catch 

fire. Regularly clean the grease filter. Never 

operate the appliance without a grease 

filter.

Risk of fire! 

Grease deposits in the grease filter may 

catch fire. Never work with naked flames 

close to the appliance (e.g. flambéing). Do 

not install the appliance near a heat-

producing appliance for solid fuel (e.g. 

wood or coal) unless a closed, non-

removable cover is available. There must 

be no flying sparks.

Risk of fire! 

Hot oil and fat can ignite very quickly. Never 

leave hot fat or oil unattended. Never use 

water to put out burning oil or fat. Switch off 

the hotplate. Extinguish flames carefully 

using a lid, fire blanket or something similar. 

Risk of fire! 

When gas burners are in operation without 

any cookware placed on them, they can 

build up a lot of heat. A ventilation 

appliance installed above the cooker may 

become damaged or catch fire. Only 

operate the gas burners with cookware on 

them.

Risk of fire! 

Operating several gas burners at the same 

time gives rise to a great deal of heat. A 

ventilation appliance installed above the 

cooker may become damaged or catch fire. 

Never operate two gas burners 

simultaneously on the highest flame for 

longer than 15 minutes. One large burner of 

more than 5 kW (wok) is equivalent to the 

power of two gas burners.

Содержание D96BMU5N0A

Страница 1: ...en Instructions for installation and use EXTRACTOR HOOD...

Страница 2: ......

Страница 3: ...ion This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer...

Страница 4: ...dows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest th...

Страница 5: ...Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a d...

Страница 6: ...onmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventil...

Страница 7: ...e is a large build up of odours and fumes vapours Switching on Touch the symbol will light up on the display Touch the symbol again to switch back to intensive mode Note After approx 6 minutes the ext...

Страница 8: ...ust be switched over accordingly The extractor hood must be connected and switched on Touch and hold the Q symbol and touch the or A symbol until 2 lights up for air recirculation mode filters that ca...

Страница 9: ...e fan will switch itself off automatically if the automatic air sensor detects no further change in the air quality in the room Automatic mode can run for a maximum of 4 hours Fan run on time Switchin...

Страница 10: ...To do this touch the A symbol Switching over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be c...

Страница 11: ...nderneath with your other hand 2 Take the metal grease filter out of the holder Notes Fat may accumulate in the bottom of the metal grease filter Hold the metal grease filter level to prevent fat from...

Страница 12: ...e metal grease filter has not been inserted correctly open the lock and reinsert the metal grease filter correctly 3Trouble shooting TroubleshootingMalfunctions often have simple explanations Please r...

Страница 13: ...ance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the accessory E no FD no After sales serviceO G...

Страница 14: ...liance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least wi...

Страница 15: ...coming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does no...

Страница 16: ...egrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The permanent electrical installation must only...

Страница 17: ...ting pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure gr...

Страница 18: ...2 Use the enclosed template to mark the positions for the screws and the outline of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for fastening the appliance and press in t...

Страница 19: ...e air pipe connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appr...

Страница 20: ...9001359222 9001359222 980615 en...

Отзывы: