materials (se picture).
WARNING!
•
Explosion risk!
The NEX MD Arm must not
be used for extracting dust or fume air mixtures in explo-
sive environments.
•
ÁËÃǾ¾Áʽƚ
Check that no sparks or other objects which
can cause fire are sucked in to the arm.
•
Éͽ½ÒÁÆ¿ÊÁËÃ
at horizontal link (
B
) on 4 m and 5 m
NEX MD arm.
User instructions
(page 5)
The extraction arm can easily be positioned at any point
within its working area. It can be rotated 180° when wall
mounted and 360° when ceiling mounted. For best capture
the hood should be positioned as near the fume or dust gene-
rating process as possible. It has the best suction capacity
when it is positioned according to figure
C
.
Recommended airflow: 900 - 1300 m
3
/h (530 - 770 cfm). Also
check local directions. The hood is equipped with a damper
which can be adjusted with a lever (
X
).
Always check that the airflow is sufficient in the hood before
work begins. Insufficient airflow is depending on:
• The fan impeller rotating in the wrong direction.
• Hood, hose and 90°-bend are blocked.
• Filter cartridges are blocked.
90°-bend in hanging or standing position
(page 5)
The NEX MD arm is recommended to be mounted according
to figure
A
, with the 90°-bend in hanging position. In excep-
tional cases the arm can be mounted according to figure
B
,
with the 90°-bend in standing position. However, the arm hol-
der must then be revolved 180°. See figure
B1
and
B2
for the
right position. Revolve the arm holder in the following way:
1.
Loosen the four screws fitting the arm holder to the 90°-
bend.
2.
Move the arm holder approximately 17 mm away from the
90°-bend.
3.
Revolve the arm holder 180°.
4.
Move the arm holder back towards the 90°-bend.
5.
Fasten the four screws.
Mounting instruction
(page 6 – 9)
The extraction arm can be mounted on wall or ceiling to-
gether with a wall bracket. Ensure that the surface, on which
to mount the arm, is level and use the wall bracket to mark
the holes.
Use locking fixing bolts and nuts suitable for the wall material.
The bolts much each stand a torque force of minimum 1200 N
(2m), 1900 N (3m), 3200 N (4m), 4500 N (5m).
Use a spirit level and make sure that the extraction arm is
fitted in a horizontal position.
Maintenance
(page 9)
Recommended at least once a year. Use necessary safety
equipment.
1.
Check that the hoses are intact. Clean the hose if it is dirty.
If necessary, change the hose.
2.
Check the mounting of the arm on wall or ceiling.
3.
Adjust the links if necessary (see page 10).
WARNING! Spring power!
Check the function of the spring
and spring holder.
4.
Check that the suction capacity in the hood is sufficient.
Adjusting the links
(page 10)
Recommended at least once a year. Use necessary safety
equipment.
A.
Adjust the inner link.
B.
Adjust the knee link.
C1.
Loosen the bellows.
C2.
Unscrew the ball joint from the hood.
C3.
Remove the bellows.
C4.
Loosen the two socket head cap screws.
C5.
Tighten the ball joint using two adjustable spanners.
C6.
Remount the ball joint at the hood and test the hood mo-
vement. If necessary, tighten the ball joint still more.
C7.
Tighten the two socket head cap screws.
C8.
Unscrew the ball joint from the hood. Refit the bellows.
Fasten the bellows at the outer arm cover. Fasten the
º¹ÄÄÂÇÁÆ̹ÌÌÀ½ÀÇǼƖƚÀ½ÆÍÌ˽»ÍÊÁÆ¿ÌÀ½
ÀÇǼÅÍË̺½ÌÁ¿À̽ƽ¼Ë½»ÍʽÄÑƖ
Technical data
Sound level*
NEX MD 2 m.................................66 dB(A)
NEX MD 3/4/5 m...........................63 dB(A)
Weight
NEX MD 2 m...................................... 17 kg
NEX MD 3 m...................................... 21 kg
NEX MD 4 m...................................... 28 kg
NEX MD 5 m...................................... 33 kg
Hose diameter ....................................................... Ø 160 mm
Recommended airflow** ................................900 - 1300 m
3
/h
Max. temperature of extracted air ................................ 120 °C
Recommended mounting height***............... 1900 - 2300 mm
This product is designed to meet the requirements of the
relevant EC directives. To maintain this status all installation,
repair and maintenance work must be carried out by qualified
personnel using only original spare parts. Contact your nea-
rest authorised dealer or AB Ph. Nederman & Co. for advice
on technical service or if you require spare parts.
* measured according to ISO 11201, at the hood and at 1700 m
3
/h.
** also apply to local directions.
*** see page 6
Содержание NEX MD 5m
Страница 4: ...4 NEX MD C max 0 4 m X B B1 NEX MD 2 m 3 m NEX MD 4 m 5 m B2 NEX MD 4 m 5 m A2 A1 NEX MD 2 m 3 m A...
Страница 5: ...5 NEX MD 230 287 225 220 11 1 NEX MD 4 m 5 m 2300 mm 1900 mm A B 2b 2a...
Страница 6: ...6 NEX MD 4 NEX MD 4 m NEX MD 5 m 5 NEX MD 4 m NEX MD 5 m 3 NEX MD 5 m 5 4 NEX MD 2 m NEX MD 3 m...
Страница 9: ...9 NEX MD C5 C4 C6 C7 C8 F B A 13 mm 1 3 m m C3 C1 C2...
Страница 23: ...23 NEX MD...