Nedap uPASS Access Скачать руководство пользователя страница 7

UPASS ACCESS | INSTALLATION GUIDE 

Connections

 

 

7/23 

3

 

CONNECTIONS 

The uPASS Access is supplied with a 5 meter (15 feet) shielded cable pigtail with 12 
multi-color wires. 
 

 RED     

Power supply 12 - 24VDC. 

 BLACK   

Power supply 0VDC, DC-Ground. 

 BROWN    RS485 A- 
 GREEN   

RS485 A+ 

 GRAY    

Data-0 / Clock 

 PINK    

Data-1 / Data 

 YELLOW   Tamper switch (normally closed) 
 GRY/PNK  Tamper switch (common) 
 RED/BLU  Led_UL_IN* 
 WHITE   

Led_NA_IN* 

 PURPLE  

Nedap antenna interface. RFMOD antenna modulation. Connect to 
ANT. 

 BLUE    

Beeper_IN* 

 SHIELD  

Shield 

 

3.1

 

POWER SUPPLY 

The uPASS Access requires DC power supply in the range from 12 – 24V. 
Maximum current consumption is 1A @ 12VDC, 0.5A @ 24VDC. 
 
Connections: 
 

 RED    

Power supply 12 - 24VDC. 

 BLACK  

Power supply 0V / DC-ground. 

SHIELD  

Shield connected to DC-ground . 

 
 

3.2

 

COMMUNICATION 

3.2.1

 

RS485 

The uPASS Access reader has a RS485 interface for communication with a host 
system or for configuring reader settings. The RS485 interface is a 2-wire half-
duplex serial communication interface using balanced lines. 

  

Connections: 
 

 BROWN    RS485 A-  

Balanced RX/TX 

GREEN   

RS485 A+ 

Balanced RX/TR 

SHIELD  

Shield connected to DC-ground. 

 

 

3.2.2

 

USB 

The uPASS Access reader features an USB interface for service, installation and 
firmware upgrade purposes. The Mini-USB connector is located on the bottom of the 
device and can only be reached when the bottom screw is opened and the uPASS 
Access is lifted away from the base-plate. This ensures that unauthorized 
modifications to the reader settings can be detected using the tamper switch. 
 
The USB interface can be used to configure the reader using the UHFTOOL software.  

 

Note 

Cable shield shall be 
connected to the metal 
case of the external 
device(s). Cable extensions 
shall only be made by 
means of shielded cable(s). 
All shields of the shielded 
cable extensions shall be 
connected together and to 
the metal case of the 
external device(s). 
Led_UL_IN, Led_NA_IN and 
Beeper_IN are inputs that 
are active LOW. 

 
 
 

Note:   

Extending this connection 
beyond the 5 meter pig tail 
length shall ONLY be 
allowed using shielded 
cable. 
The minimum voltage at the 
end of the fixed shieled 
pigtail cable shall be 
greater then 12VDC -10% 
The shield shall be 
connected to the metal 
case of the external device. 

 

Note:   

The RS485 interface is 
disabled while the USB 
interface is in use! 
Extending this connection 
beyond the 5 meter pig tail 
length shall ONLY be 
allowed using shielded 
twisted pair cable(2 x 2 x 
0.25 mm2) as long as the 
total length is shorter then 
1200 meters, 6000 feet, 
cable capacity < 100 
pF/meter. 
The second twisted pair 
shall be used for the DC 
power supply. 
The shield shall be 
connected to the metal 
case of the external device. 

 
 
 
 
 
 

Note 

While the shielded USB 
cable is connected, the 
RS485 interface is disabled! 
The maximum shielded 
cable length shall be < 2 
meter. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Note 

Extending these 
connections beyond the 5 
meter pig tail length shall 
ONLY be allowed using 
shielded cable (4 x 0.25 
mm2) as long as the total 
length is shorter than 1200 
meters (4000 feet).     
The shield shall be 
connected to the metal 
case of the external device. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание uPASS Access

Страница 1: ...uPASS ACCESS installation guide 2016 03 16 v4 4 Doc no 5281326...

Страница 2: ...EQUENCIES____________________________________________________ 11 4 1 RADIO REGULATIONS ___________________________________________ 11 4 2 FREQUENCY CHANNEL SELECTION________________________________ 11...

Страница 3: ...e There is no need to change any DIP switches or configuration settings See chapter 3 2 3 for wiring details NEDAP UHF XS tag These tags are especially programmed in the same format as our 2 45GHz AVI...

Страница 4: ...is supported in combination with all NEDAP UHF tags By default the uPASS Access reader is configured to read any EPC tag We encourage customers to enable the TID check or the two way authentication B...

Страница 5: ...cess is NOT hot swappable so when making or changing connections power must be switched OFF The cable shield shall be connected with safety ground and the metal case of the external device s To be sur...

Страница 6: ...the 2 screws When mounting on a stone or concrete wall drill 5mm holes for the plugs When mounting on wood drill with 2 5mm Install the uPASS Access reader onto the base plate 1 Feed the cable throug...

Страница 7: ...rized modifications to the reader settings can be detected using the tamper switch The USB interface can be used to configure the reader using the UHFTOOL software Note Cable shield shall be connected...

Страница 8: ...te a message on this interface unless the Extra output settings are used The Wiegand magstripe output format is determined by the programmed format of the tag Make sure to order the correct tag format...

Страница 9: ...220 sec Data pre amble 16 clock periods Data post amble 16 clock periods Figure 4 Magstripe protocol timing one character 3 3 LED CONTROL The built in high intensity LED provides visual feedback that...

Страница 10: ...cess to NEDAP AEOS access control hardware such as the AP1001 Instead of proximity antenna the uPASS Access can be connected Connections PURPLE Nedap antenna interface RFMOD antenna modulation Connect...

Страница 11: ...quency band is divided into frequency channels If local radio regulations require frequency hopping FHSS then the uPASS Access automatically selects and uses the available channels 4 2 FREQUENCY CHANN...

Страница 12: ...gories are shown Expand or collapse the setting panels by clicking on it 5 2 1 READ DATA Configure here which tags should be selected how to access these tags what data should be read from these tags...

Страница 13: ...UPASS will not perform any decoding Enable decode Nedap XS when you do not want to use the TRANSIT compatible processor or the antenna modulation interface The UPASS will decode the NEDAP XS tag data...

Страница 14: ...o activate the relay upon identification When disabled the relay can only be activated manually The Relay hold time setting is the minimum time the relay is activated The Vehicle hold time setting is...

Страница 15: ...hen this option is disabled the message is only transmitted once This setting has no effect when using the Wiegand or magstripe interface On the Wiegand or magstripe interface the identification messa...

Страница 16: ...nd Enable additional Wiegand output Magstripe Enable additional magstripe output Data source EPC number Output the EPC number using the selected protocol Custom read data Output the custom data read u...

Страница 17: ...ple 1 Example 2 Output the 13 rightmost digits from the EPC number using the magstripe interface Figure 14 Additional output example 2 5 3 4 FREQUENCY Here is shown the reader s operating frequency re...

Страница 18: ...ane separation When the squelch is enabled you can set the squelch level This level ensures that only tags with a returned signal strength higher than the squelch level are identified When the squelch...

Страница 19: ...e extensions beyond the 5 meter shall ONLY be allowed using shielded cable Interfaces RS485 and USB USB local service only Air interface ISO18000 6C Operating frequency Country Frequency Technique Pow...

Страница 20: ...INSTALLATION GUIDE Part Numbers 20 23 B PART NUMBERS Readers NEDAP uPASS Access Region 1 EUR 865 868 MHz NEDAP uPASS Access Region 2 USA 902 928 MHz NEDAP uPASS Access Region 3 915 928 MHz 9958240 920...