UPASS ACCESS | INSTALLATION GUIDE
Reader Configuration
15/23
Figure 10: LED control
Remote control:
The LED can be controlled remotely by a connected access control system. Digital
inputs will determine the color indicated on the LED.
5.3
EXPERT SETTINGS
Click 'Options', 'Usermode', 'Expert' to show additional configuration settings for
advanced users.
5.3.1
OUTPUT
Configure communication output settings.
Figure 11: Output settings
Select 'Enable serial id-events' to enable the serial output upon identification. Only
disable the serial id-events to optimize the identification speed when using the
Wiegand or magstripe interface or the TRANSIT compatible processor.
When 'Fast repeat serial id-events' is selected (default) the serial output is repeated
upon every identification. When this option is disabled, the message is only
transmitted once.
This setting has no effect when using the Wiegand or magstripe interface. On the
Wiegand or magstripe interface the identification message is always only
transmitted once when the tag is within the range of the reader.
Enable 'Repeat using hold-time interval' to periodically repeat the id-events as long
as the tag is within the identification range. Set the hold-time to specify the interval
between the repeated messages. The repeating will be enabled for the serial and
also for the Wiegand or magstripe interface.
'Enable vehicle id-events' allows enabling or disabling the id-event messages for
vehicle-ids. This may be useful in combination with the NEDAP DUAL-ID mode and
an access control panel that does not support the dual-id feature.
5.3.2
OUTPUT MESSAGE FORMAT
Configure output message format.
Note
When the output message
format is changed,
identified tags may no
longer be shown in the
UHFTOOL.