37 NED
XCM8040SAT4 UME-0038-02
4.8
Exposure Mode and Timing Chart
The camera has three exposure modes. The overview of each mode and the
timing are as follows.
4.8.1 Free Run Exposure Mode (Programming time setting)
In free-run exposure mode, the camera generates its own internal control
signal based on two programmable parameters, exposure time and readout
time.
Table 4-8-1-1 Programmable Exposure Time
p
Programable exposure time
48.8
~
1676083.2
r
Readout time
51.2
(
Unit:
μs
)
Exposure
Readout
(1)
(1)
(2)
(2)
(3)
(3)
(4)
(4)
(5)
p
r
scan
Figure 4-8-1-1 Free Run Exposure Mode
The data of Exposure (1) is read out at Readout (1)