background image

© by NECTA VENDING SOLUTIONS SpA

50

01 10 126-03

Fig. 15

1 - Selector opening cam
2 - Coin chute
3 - Openings for plastic inserts

INSTALLING THE PAYMENT SYSTEM

The machine is sold without payment system, therefore
the installer of such a system has sole responsibility for
any damage to the machine or to things and persons
caused by incorrect installation.

- Fit the coin mechanism and make sure that the selec-

tor coin inlet and the coin return lever are aligned with
the coin chute and the selector opening cam;

- according to the type of coin mechanism, to achieve

such alignment move the plastic inserts in the adjacent
openings;

- ensure that all relevant parameters are programmed

correctly.

CONNECTING THE MACHINE
TO THE POWER SUPPLY

The machine is designed to operate under single-phase 230
V~ voltage and is protected by 10 A fuses.
Before making the connection ensure that the rating corre-
sponds to that of the power grid, and more specifically:

- the supply voltage rating should be within the range

recommended for the connection points;

- the main switch should be suitable to withstand the

peak load required, and at the same time should
ensure proper omnipolar disconnection from the
power grid with an opening gap of the contacts of at
least 3 mm.

The main switch, the power outlet and the plug should
be located within easy reach.

The electrical safety of the machine is ensured only when
it is correctly earthed according to the safety standards in
force.

This fundamental safety requirement must be duly verified,
and if in doubt the system must be carefully tested by quali-
fied technicians.
The power cable must be fitted with a fixed plug.
Any replacement of the power cable should be made by
qualified and suitably trained personnel only using cables
type HO5 RN-F, HO5 V V-F or H07 RN-F with a 3x1.5 mm

2

section.

Do not use adapters, multiple sockets and/or exten-
sions.

THE MANUFACTURER DECLINES ALL RESPONSIBIL-
ITY FOR ANY DAMAGE CAUSED BY NONCOMPLI-
ANCE WITH THE ABOVE MENTIONED PRECAUTIONS.

CONFIGURATION OF THE
DISPENSING MODULES

Should it be necessary to change the size of the products
to be dispensed, the dispensing modules for cans or the
columns (single and double) can be reconfigured by using
some elements available as optional.

The machine is supplied with a table containing details
of the settings as determined by the manufacturer
during tests and experiments performed with the most
common product types.

Settings for other product types can be determined by
following the information indicated below.

In any case it will be necessary to test each module to
be sure of its correct operation.

Products which are too irregular or not firm enough may not
be suitable for automatic dispensing.

DISPENSING MODULES FOR CANS

The modules can be adapted for dispensing 250, 330 and
355 cc cans by simply replacing the guides fitted at the inlet
of the two upper chutes with others which are adequately
sized.
The guide has the function of preventing the cans from
rotating and getting into a transverse position.
The guides are secured to the left hand wall of the module
(see Fig. 6) and are fixed with only one screw.

COLUMNS

The columns can be adapted for dispensing:

- 62 to 73 mm dia. bottles with 246 to 285 mm height in

a single row;

- 62 to 73 mm dia. bottles with 196 to 246 mm height in

a double row;

- 66 mm dia., 250 cc - 330 cc - 355 cc cans in quadruple

row.

The following procedure must be adopted.

According to the type of bottle it will be necessary to
make some adjustments to the settings indicated be-
low.

Содержание Zeta CB Series

Страница 1: ...MANTENIMIENTO INSTALLATION BEDIENUNG WARTUNG HANDBOEK VOOR GEBRUIK INSTALLATIE ONDERHOUD IT Italiano Pagina 1 FR Fran ais Page 21 UK English Page 41 ES Espa ol P gina 61 DE Deutsch Seite 81 NL B Nede...

Страница 2: ......

Страница 3: ...a de identificaci n resulta conforme a las disposiciones legislativas de las directivas 89 392 89 336 73 23 CEE y modificaciones y integraciones sucesivas Declara que o distribuidor descrita na chapa...

Страница 4: ......

Страница 5: ...PAGE 4 POWER CONSUMPTION PAGE 4 VARIABLE COMBINATION LOCK PAGE 45 LOADING AND CLEANING PAGE 45 DOOR SWITCH PAGE 45 DISPENSING MODULES PAGE 45 CONTROLSAND INFORMATION PAGE 47 LOADING PAGE 47 RELEASING...

Страница 6: ...hine Thereforeitmustalwaysfollowthemachine whenitis moved or ownership is transferred so that different operators may be able to consult it Beforeinstallingandusingthemachine itisfirstnecessary tocare...

Страница 7: ...sons caused by incorrect installation Theintegrityofthevendingmachineanditsconformity with the rules and regulations in force for its relevant systems must be checked by qualified personnel at least o...

Страница 8: ...l o v y l p p u S 0 3 2 0 3 2 0 3 2 z H y c n e u q e r f y l p p u S 0 5 0 5 0 5 W r e w o p d e l l a t s n I 0 5 7 0 5 7 0 0 8 V p m a l t r o h s r o o D 0 3 2 0 3 2 0 3 2 W p m a l t r o h s r o...

Страница 9: ...icro switchdisconnects the power from the electrical system of the machine to allowtheloadingandroutinecleaningoperationsdescribed below in full safety All operations requiring the machine to be energ...

Страница 10: ...o switch 5 Limit micro switch Fig 7 1 Double column 2 Single column 3 Rotor The columns can be preset for dispensing 66 dia cans or round bottles with a diameter range of 62 to 73 mm Warning glass bot...

Страница 11: ...the chute inlet and let them roll down It is not important which side the top of the can is facing Should a product chute be completely empty for ex whenfirstinstallingthemachine afterloadingmakea sel...

Страница 12: ...ATURE CONTROL Thethermostatisinitiallyadjustedsothatatemperatureof 1 5 Cismaintainedinthelowerportionoftherefrigerated box containing bottles and cans which will be sold first The thermostat is locate...

Страница 13: ...outlet remove all products from the columns and clean the inside and all accessories INSTALLATION The machine installation and the following maintenance operations should be carried out with the machi...

Страница 14: ...the power cable should be made by qualified and suitably trained personnel only using cables type HO5 RN F HO5 V V F or H07 RN F with a 3x1 5 mm2 section Do not use adapters multiple sockets and or e...

Страница 15: ...s 2 65 66 67 mm thickness 3 68 69 70 mm thickness 4 Short adapting plate 5 Long adapting plate The rotor insert can be identified by the dispensed product diameter printed on the element To install or...

Страница 16: ...LEMENTS The anti friction elements are frames made of special plastic material which facilitate product sliding For dispensing bottles the anti friction elements are fitted onthedoublecolumnbafflesand...

Страница 17: ...mn back panel BOTTLE GUIDES FOR SINGLE COLUMNS The bottle guides have the function of keeping bottles with a tapered neck correctly aligned so that they do not tilt forward Forsinglecolumns theguidesa...

Страница 18: ...hrough an opening with a width less than the smallest dimensionofthemachine thedoorandthedoorframecan be removed to temporarily reduce the depth to 750 mm The disassembly and reassembly operations mus...

Страница 19: ...validator Serial interface for MDB coin mechanism Programming of the number of selections 1 to 10 Programming of the vending price for each single selection Time out function for the vending motors a...

Страница 20: ...lection is blocked the corresponding button is illuminated Whenpressingtheilluminatedbutton thedisplayindicates if the cause of the blockage is an empty module and ifthecauseisaproblemconnectedwiththe...

Страница 21: ...machine code 6th digit of machine code Time of cycle start Motor safety time 0 to 30 seconds Initialising Countersdisplay The setting sequence of the parameters varies according to the type of interfa...

Страница 22: ...se minimum 1 maximum 10 columns then press button 2 to store the new data unit and go to the next parameter x is the number of selections It can be set to values varying from 1 to 10 default 6 Type of...

Страница 23: ...e MDB only It is the value of the maximum amount of change returned If set to 0 the maximum possible value is returned Multiple sales MDB only This function is used to make available to the user any a...

Страница 24: ...n 2 each time the illuminated button indicates the selection to which the value on the display is referred Toresetavaluepressbutton5 thedisplaywillberesetand the next data unit will automatically be d...

Страница 25: ...BOARD SM CONTROL BOARD ST STARTER TERM THERMOSTAT TR TRANSFORMER TX DELAYED FUSE X COURRENT SIGLA DENOMINACION MEMORIA ESQUEMA ELECTRICO BDV CONNECTOR PARA MONEDERO BDV CF CONDENSADOR DEL FILTRO COM C...

Страница 26: ...NECTA VENDING SOLUTIONS SpA Sx34002...

Страница 27: ...Zeta 550 9...

Страница 28: ...NECTA VENDING SOLUTIONS SpA Sx34400...

Страница 29: ...Zeta 550 6...

Страница 30: ...NECTA VENDING SOLUTIONS SpA Sx34700...

Страница 31: ...Zeta 450 5...

Страница 32: ...NECTA VENDING SOLUTIONS SpA Sx35100...

Страница 33: ...Zeta 450 7...

Страница 34: ...NECTA VENDING SOLUTIONS SpA Sx35300...

Страница 35: ...Zeta 750 9...

Страница 36: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Страница 37: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Страница 38: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Страница 39: ...smitted to third parties without the written permit of the Manufac turer who has the sole ownership Le fabricant se r serve le droit de modifier sans pr avis les caract ristiques des appareils pr sent...

Страница 40: ......

Отзывы: