background image

© by NECTA VENDING SOLUTIONS SpA

56

01 10 126-03

PAYMENT SYSTEMS

Interface with "Executive" coin mechanism

Connect the coin mechanism to the 15-pin molex power
supply connector and to connector CN1 on the control board.
Set the board as described in the "Programming of param-
eters and prices" section.
Set the two minidips (SW2) to OFF position.

Interface with MDB coin mechanism

Connect the coin mechanism to connector CN2 and ener-
gise the board with 24 V ac through connector CN19 using
the special cable. Set the board as described in the
"Programming of parameters and prices" section.
Set the two minidips (SW2) to ON position.

Interface with 24 Vvalidator

The validator must be connected to connector CN5 on the
board (see Fig. 27). Set the board as described in the
"Programming of parameters and prices" section.

Free vend for all selections

Place minidip 5 into position “ON”.

MINIDIP FUNCTIONS

Each of the 6 minidip (SW1), when moved to position "ON",
activates one of functions indicated below.
The two SW2 minidips have the following functions:
1-2 ON = payment system MDB
1-2 OFF = payment system Executive

1 - ON = Programming of parameters and sales prices
2 - ON = Reading on the display the stored data
3 - ON = Not used
4 - ON = Total sales display
5 - ON = Free vend
6 - ON = Motor reset

Motor reset

When one or more selections are blocked and the motor
cams are out of position, placing minidip 6 into position
"ON" automatically resets all blocked motors.
When a selection is blocked, the corresponding button is
illuminated.
When pressing the illuminated button, the display indicates

 if the cause of the blockage is an empty module

and 

  if the cause is a problem connected with the

motor or with the micro-switch of that column.

Instant display of total sales

Placing minidip 4 into position "ON" causes the total sales
information to be shown on the display, thus skipping the
normal "data" procedure. After storing this value, minidip 4
must be placed back to position "OFF".

Automatically unloading the columns

Simultaneously placing minidip 4 and 6 into position "ON"
enables the function used to automatically unload the
columns.
After closing the door the message  

 will be

displayed; pressing the button of the selection to be
emptied causes the release motor to be activated at
intervals of five seconds and up to 30 consecutive selec-
tions maximum.

The motor will continue for other four selections after the
signal of "empty" condition.
The automatic unload function can be interrupted by
pressing any button during the 5 second interval between
two releases.

PROGRAMMING OF PARAMETERS
AND PRICES

Place minidip 1 into position "ON".
The indication 

 will be displayed.

Now the last four selection buttons are illuminated and are
given the following functions:

Fig. 28

BUTTON

FUNCTION

Decrease value

Increase value

Store data unit and/or skip to the
next step

Enter/exit programming mode

Reset data (read only mode)

Interface with 24 V validator

No. of selections 1 to 10

Executive Interface

Access program

Enter

Increase

SELECTION BUTTONS

Decrease

MDB interface

COGES Interface

Price Holding interface

U-key Interface

Содержание Zeta CB Series

Страница 1: ...MANTENIMIENTO INSTALLATION BEDIENUNG WARTUNG HANDBOEK VOOR GEBRUIK INSTALLATIE ONDERHOUD IT Italiano Pagina 1 FR Fran ais Page 21 UK English Page 41 ES Espa ol P gina 61 DE Deutsch Seite 81 NL B Nede...

Страница 2: ......

Страница 3: ...a de identificaci n resulta conforme a las disposiciones legislativas de las directivas 89 392 89 336 73 23 CEE y modificaciones y integraciones sucesivas Declara que o distribuidor descrita na chapa...

Страница 4: ......

Страница 5: ...PAGE 4 POWER CONSUMPTION PAGE 4 VARIABLE COMBINATION LOCK PAGE 45 LOADING AND CLEANING PAGE 45 DOOR SWITCH PAGE 45 DISPENSING MODULES PAGE 45 CONTROLSAND INFORMATION PAGE 47 LOADING PAGE 47 RELEASING...

Страница 6: ...hine Thereforeitmustalwaysfollowthemachine whenitis moved or ownership is transferred so that different operators may be able to consult it Beforeinstallingandusingthemachine itisfirstnecessary tocare...

Страница 7: ...sons caused by incorrect installation Theintegrityofthevendingmachineanditsconformity with the rules and regulations in force for its relevant systems must be checked by qualified personnel at least o...

Страница 8: ...l o v y l p p u S 0 3 2 0 3 2 0 3 2 z H y c n e u q e r f y l p p u S 0 5 0 5 0 5 W r e w o p d e l l a t s n I 0 5 7 0 5 7 0 0 8 V p m a l t r o h s r o o D 0 3 2 0 3 2 0 3 2 W p m a l t r o h s r o...

Страница 9: ...icro switchdisconnects the power from the electrical system of the machine to allowtheloadingandroutinecleaningoperationsdescribed below in full safety All operations requiring the machine to be energ...

Страница 10: ...o switch 5 Limit micro switch Fig 7 1 Double column 2 Single column 3 Rotor The columns can be preset for dispensing 66 dia cans or round bottles with a diameter range of 62 to 73 mm Warning glass bot...

Страница 11: ...the chute inlet and let them roll down It is not important which side the top of the can is facing Should a product chute be completely empty for ex whenfirstinstallingthemachine afterloadingmakea sel...

Страница 12: ...ATURE CONTROL Thethermostatisinitiallyadjustedsothatatemperatureof 1 5 Cismaintainedinthelowerportionoftherefrigerated box containing bottles and cans which will be sold first The thermostat is locate...

Страница 13: ...outlet remove all products from the columns and clean the inside and all accessories INSTALLATION The machine installation and the following maintenance operations should be carried out with the machi...

Страница 14: ...the power cable should be made by qualified and suitably trained personnel only using cables type HO5 RN F HO5 V V F or H07 RN F with a 3x1 5 mm2 section Do not use adapters multiple sockets and or e...

Страница 15: ...s 2 65 66 67 mm thickness 3 68 69 70 mm thickness 4 Short adapting plate 5 Long adapting plate The rotor insert can be identified by the dispensed product diameter printed on the element To install or...

Страница 16: ...LEMENTS The anti friction elements are frames made of special plastic material which facilitate product sliding For dispensing bottles the anti friction elements are fitted onthedoublecolumnbafflesand...

Страница 17: ...mn back panel BOTTLE GUIDES FOR SINGLE COLUMNS The bottle guides have the function of keeping bottles with a tapered neck correctly aligned so that they do not tilt forward Forsinglecolumns theguidesa...

Страница 18: ...hrough an opening with a width less than the smallest dimensionofthemachine thedoorandthedoorframecan be removed to temporarily reduce the depth to 750 mm The disassembly and reassembly operations mus...

Страница 19: ...validator Serial interface for MDB coin mechanism Programming of the number of selections 1 to 10 Programming of the vending price for each single selection Time out function for the vending motors a...

Страница 20: ...lection is blocked the corresponding button is illuminated Whenpressingtheilluminatedbutton thedisplayindicates if the cause of the blockage is an empty module and ifthecauseisaproblemconnectedwiththe...

Страница 21: ...machine code 6th digit of machine code Time of cycle start Motor safety time 0 to 30 seconds Initialising Countersdisplay The setting sequence of the parameters varies according to the type of interfa...

Страница 22: ...se minimum 1 maximum 10 columns then press button 2 to store the new data unit and go to the next parameter x is the number of selections It can be set to values varying from 1 to 10 default 6 Type of...

Страница 23: ...e MDB only It is the value of the maximum amount of change returned If set to 0 the maximum possible value is returned Multiple sales MDB only This function is used to make available to the user any a...

Страница 24: ...n 2 each time the illuminated button indicates the selection to which the value on the display is referred Toresetavaluepressbutton5 thedisplaywillberesetand the next data unit will automatically be d...

Страница 25: ...BOARD SM CONTROL BOARD ST STARTER TERM THERMOSTAT TR TRANSFORMER TX DELAYED FUSE X COURRENT SIGLA DENOMINACION MEMORIA ESQUEMA ELECTRICO BDV CONNECTOR PARA MONEDERO BDV CF CONDENSADOR DEL FILTRO COM C...

Страница 26: ...NECTA VENDING SOLUTIONS SpA Sx34002...

Страница 27: ...Zeta 550 9...

Страница 28: ...NECTA VENDING SOLUTIONS SpA Sx34400...

Страница 29: ...Zeta 550 6...

Страница 30: ...NECTA VENDING SOLUTIONS SpA Sx34700...

Страница 31: ...Zeta 450 5...

Страница 32: ...NECTA VENDING SOLUTIONS SpA Sx35100...

Страница 33: ...Zeta 450 7...

Страница 34: ...NECTA VENDING SOLUTIONS SpA Sx35300...

Страница 35: ...Zeta 750 9...

Страница 36: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Страница 37: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Страница 38: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Страница 39: ...smitted to third parties without the written permit of the Manufac turer who has the sole ownership Le fabricant se r serve le droit de modifier sans pr avis les caract ristiques des appareils pr sent...

Страница 40: ......

Отзывы: