Start-Up Problems
The system displays an invalid configuration error message at power on when there are the following
conditions:
the current configuration information doesn't match configuration information stored in Auto Setup,
such as when an internal option is added.
the system loses configuration information.
If either condition is true, the system displays an "invalid configuration information" message.
To continue start-up procedures, press
F2
(or
F1
when prompted) and run the Setup utility to set current
system parameters.
If an error message appears before the operating system starts, look up the error message in the following
table. Follow the instructions. If you see other error messages, the hardware might need repairing.
If the system frequently loses the Setup configuration data, the internal CMOS battery may need to be
replaced at an authorised repair centre.
Post Error Messages
The Versa notebook has a built-in checking program that automatically tests its components when you turn
the system power on. This diagnostic test is called the Power-On Self-Test (POST). If the system finds a
problem during the POST, the system displays an error message. If this happens, follow the instructions in the
POST Error Messages table.
Message
Resolution
Failure Fixed Disk Fixed disk is not configured or working properly. Check to see if the fixed disk is
attached properly.
Run Setup
. Find out if the fixed-disk type is correctly identified.
Stuck Key
A key is stuck on the keyboard.
Keyboard error
The keyboard is not working. Try replacing it.
Keyboard
Controller failed
The keyboard controller failed test. You may have to replace the keyboard controller.
Extended RAM
Failed at offset:
nnnn
Extended memory not working or not configured properly at offset nnnn.
System RAM
Failed at offset:
nnnn
System memory not working or not configured properly in the 64k block in which the
error was detected.
Shadow RAM
Failed at offset:
nnnn
Shadow memory not working or not configured properly in the 64k block in which the
error was detected.
System battery is
dead - Replace
and run Setup
The CMOS clock battery indicator is dead. Contact your authorised service
representative to replace the battery.
System CMOS
checksum bad -
replace and run
SETUP
CMOS has been corrupted or modified incorrectly, perhaps by an application program
that changes data stored in CMOS. Run
Setup
and reconfigure the system either
using the Default Values and/or making your own selections.
System CMOS
checksum bad -
Default
configuration used
CMOS has been corrupted or modified incorrectly, perhaps by an application program
that changes data stored in CMOS. The BIOS used the default values. If necessary,
run Setup
and reconfigure the system by making your own selections. If the error
persists, contact your authorised service representative.
System timer error The timer test failed. Requires repair of the system board.
Real time clock
Real-time clock fails BIOS test. It may require board repair.
Start-Up Problems
Содержание Versa 2730M
Страница 1: ...Versa User s Guide Versa User s Guide ...
Страница 15: ...Copyright Copyright ...
Страница 17: ...Introducing Your Versa Getting to Know your Versa ...
Страница 19: ...Around the Front of the System Around the Front of the System ...
Страница 25: ...Around the Back of the System Around the Back of the System ...
Страница 27: ...Around the Left Side of the System Around the Left Side of the System ...
Страница 29: ...Around the Right Side of the System Around the Right Side of the System ...
Страница 31: ...Around the Bottom of the System Around the Bottom of the System ...