CHAPTER 11 10-BIT A/D CONVERTER (
µ
PD789436 AND 789456 SUBSERIES)
User’s Manual U15075EJ2V1UD
211
(5) Timing of undefined A/D conversion result
The A/D conversion value may become undefined if the timing of the completion of A/D conversion and that
to stop the A/D conversion operation conflict. Therefore, read the A/D conversion result while the A/D
conversion operation is in progress. To read the A/D conversion result after the A/D conversion operation
has been stopped, stop the A/D conversion operation before the next conversion operation is completed.
Figures 11-8 and 11-9 show the timing at which the conversion result is read.
Figure 11-8. Conversion Result Read Timing (If Conversion Result Is Undefined)
End of A/D conversion
End of A/D conversion
Normal conversion result
Undefined value
Normal conversion result is read.
A/D conversion
stops.
Undefined value
is read.
ADCR0
INTAD0
ADCS0
Figure 11-9. Conversion Result Read Timing (If Conversion Result Is Normal)
Normal conversion result
End of A/D conversion
Normal conversion
result is read.
A/D conversion stops.
ADCR0
INTAD0
ADCS0