Issue 3.0
UNIVERGE SV8100
5 - 18
Hardware Specifications
5.4.7
External Tone Ringer/Night Chime Output
Output Level: –10 dBm
Output Impedance: 600
Relay Contact Rating: 500 mA, 24 Vdc
5.4.8
SMDR Output
Female Connector (LAN) Standard DB-9 (straight)
5.4.9
PC Connection
Female Connector (LAN) Standard DB-9 (straight)
5.4.10
Relay Contact
All Relay Contact Ratings: 500 mA, 24Vdc
5.5
Battery Backup
The UNIVERGE SV8100 system has battery backup functions for system
backup and for memory backup.
5.5.1
System Backup (Optional)
During a power failure, the system can be backed up using the
CHS2U BATT MTG KIT for a backup time of 10 minutes or one of the
CHS LARGE BATT SETs for a backup time ranging from 45~180
minutes. The CHS2U GW-US can be backed up using the CHSGW
SMALL BATT BOX for a backup time of 10 minutes.
5.5.2
Memory Backup
The CD-CP00-US blade battery retains the Clock/Calender and Last
Number redial (LNR) buffers for each station when the CD-CP00-US
blade encounters a power loss. With a fully charged battery, the
settings are retained for about three years. The System Programmed
memory (Customer Database) is stored in nonvolatile Memory and
can be erased only by a First Initialization. After power is restored,
the system blade returns to normal operation.
Содержание UNIVERGE SV810
Страница 2: ......
Страница 3: ...General Description Manual INT 2069 UNIV ISSUE 3 0 Version 2500 ...
Страница 4: ......
Страница 6: ......
Страница 20: ...Issue 3 0 UNIVERGE SV8100 R 12 Regulatory NOTES ...
Страница 122: ...Issue 3 0 UNIVERGE SV8100 2 82 Features THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 132: ...Issue 3 0 UNIVERGE SV8100 3 10 Equipment THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 162: ...Issue 3 0 UNIVERGE SV8100 5 26 Hardware Specifications THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 163: ......
Страница 164: ...GENERAL DESCRIPTION MANUAL NEC Unified Solutions Inc Issue 3 0 Version 2500 ...