UNIVERGE SV8100
Issue 3.0
General Description Manual
5 - 11
S
ECTION
4
P
OWER
R
EQUIREMENTS
A dedicated 100VAC/
120VAC/220VAC/230 – 240VAC
50Hz/60Hz circuit located within
seven feet of the chassis is required. A separate dedicated outlet for each chassis
should be installed.
4.1
Power Supply Specifications
AC Power Supply:
Dedicated 15 Amp circuit
Power Requirements: 120 VAC @ 15A Controlling/Base Chassis
Power Consumption: Base Chassis=263VA,
Expansion Chassis=263VA, total 1052VA
Input Voltage: 90VAC to 264VAC
(Rated Voltage: 100VAC/120VAC/220VAC - 240VAC)
Frequency:
47Hz – 63Hz (Rated frequency: 50/60Hz)
Phase and Wire: Single Phase, 2 Line + PE Type
Grounding Requirements: No. 14 AWG copper wire
Feeding Voltage:
D
term
/OPX/DID: -48V
SLT: 25mA / -28V
With input voltage of 120 VAC and with full load conditions:
Output Power: Base chassis=130W, Expansion chassis=130W, total 520W
AC Input I: Base chassis=2.19A, Expansion chassis=2.19A, total 8.76A
VA @ 120V: Base chassis=263VA, Expansion chassis=263VA,
total 1052VA
Table 5-8 Cabling Requirements
Connected Equipment
Cable
Music on Hold and Background Music Sources
Hi-Fi Shielded Audio Cable
External Amplifier
Hi-Fi Shielded Audio Cable
ITL Cabling
Cat 5 Straight Data Network
Cable – 328.1 ft (100m)
maximum distance.
Double Pole/Neutral Fusing (power supply fuses are located at
both the L and N side).
Содержание UNIVERGE SV810
Страница 2: ......
Страница 3: ...General Description Manual INT 2069 UNIV ISSUE 3 0 Version 2500 ...
Страница 4: ......
Страница 6: ......
Страница 20: ...Issue 3 0 UNIVERGE SV8100 R 12 Regulatory NOTES ...
Страница 122: ...Issue 3 0 UNIVERGE SV8100 2 82 Features THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 132: ...Issue 3 0 UNIVERGE SV8100 3 10 Equipment THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 162: ...Issue 3 0 UNIVERGE SV8100 5 26 Hardware Specifications THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 163: ......
Страница 164: ...GENERAL DESCRIPTION MANUAL NEC Unified Solutions Inc Issue 3 0 Version 2500 ...