Issue 3.0
UNIVERGE SV8100
5 - 12
Hardware Specifications
KWh @ AC Input I x 120V/1000: Base chassis=0.263 KWh,
Expansion chassis=0.263 KWh, total 1.052 KWh
BTU (KWh x 3413): Base chassis=898 BTU,
Expansion chassis=898 BTU, total 3592 BTU
Dedicated 120 Vac
60 Hz circuit located within seven feet of the chassis
Dedicated 15A circuit
Single Phase
A dedicated outlet, separately fused and grounded for each chassis should
be installed
4.2
Power Supply Consumption
S
ECTION
5
E
NVIRONMENTAL
C
ONDITIONS
5.1
Temperature and Humidity
Chassis, Telephones, BCH, BHA, 16LK, Console, ADA, APR
Operating Temperature: +32°F ~ +104°F (0°C ~ 40°C)
Recommended Long Term Temperature: -4°F ~ +140°F (-20°C ~ 60°C)
Operating Humidity: 10 ~ 90% RH (non-condensing)
Recommended Long Term Humidity: 10 ~ 90% RH
Table 5-9 Power Consumption
Chassis
Maximum
RMS
Current
Watts Used
(Idle)
Watts Used
(Maximum)
Basic Chassis – CD-CP00-US Chassis
2.19A
96
130
Basic C Expansion Chassis
4.38A
192
260
Basic C 2 Expansion Chassis
6.57A
288
390
Basic C 3 Expansion Chassis
8.76A
384
520
Double Pole/Neutral Fusing (power supply fuses are
located at both the L and N side).
Double Pole/Neutral Fusing (power supply fuses are
located at both the L and N side).
Содержание UNIVERGE SV810
Страница 2: ......
Страница 3: ...General Description Manual INT 2069 UNIV ISSUE 3 0 Version 2500 ...
Страница 4: ......
Страница 6: ......
Страница 20: ...Issue 3 0 UNIVERGE SV8100 R 12 Regulatory NOTES ...
Страница 122: ...Issue 3 0 UNIVERGE SV8100 2 82 Features THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 132: ...Issue 3 0 UNIVERGE SV8100 3 10 Equipment THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 162: ...Issue 3 0 UNIVERGE SV8100 5 26 Hardware Specifications THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 163: ......
Страница 164: ...GENERAL DESCRIPTION MANUAL NEC Unified Solutions Inc Issue 3 0 Version 2500 ...