CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 82 –
NWA-008847-001 Rev.3.0
a6ch1001.fm
Output example:
If the following are set,
First data 00 ..... command code 05
First data 10 ..... command code 06
command of command code 05 or command code 06 is output (OR condition).
If the following are set,
First data 00 ..... command code 05
First data 01 ..... FP No.00
command is output that FP No. is 00 at command code 05 (AND condition).
(11) The conditions for outputting commands to RS-232C are as follows.
• Traffic when setting data transmission speed to 9600bps will be below 2500BHC. Traffic when
setting data transmission speed to 19200bps will be below 5000BHC.
• Command output will be automatically stopped after approximately 16 seconds if the cable has
been disconnected during command output. Data in buffer memory remains stored.
(12) The conditions for outputting an MP-FP command to a built-in modem are as follows.
• Traffic should be below 2000BHC.
• Command output will be stopped immediately if the modem line is disconnected. Stored
commands and command output settings (set by CMF6 Y=2>06) will be cleared.
• Automatic notification is impossible.
• A built-in modem will be automatically disconnected if non-communication status lasted for 10
minutes. Non-communication status continues and a built-in modem may be disconnected if you
assign a command that is not output for a long time.
JULY/01/2006
ONLINE MP-FP COMMAND OUTPUT
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Страница 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Страница 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Страница 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...