CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 51 –
NWA-008847-001 Rev.3.0
a6ch1001.fm
Programming Procedure
DESCRIPTION
DATA
Assign whether the system clock is set
when the system clock setting command is
received from the RMAT.
(1) 456
(2) 0
: Not set
1
: To set
Assign whether the fault information is
cleared when the fault information clear
command is received from the RMAT.
(1) 457
(2) 0
: To clear
1
: Not cleared
Assign the station number of the MP built-
in modem.
• Y=10
(1) 1
(2) X-XXXXXXXX: Station No.
Assign the function of analog data station
to the required modem station number.
• Y=07
(1) X-XXXXXXXX: Station No.
(2) 0
: Data station
Specify the recall interval timer of the MP
built-in modem.
• Y=0
(1) 69
(2) 45-99: 180-396 seconds
(4 second increments)
If no data is set, the default setting is
304 seconds.
Specify the number of times for recall from
the MP built-in modem.
(1) 19
(2) 01-09: Number of times
If no data is set, the default setting is 04.
Allocate the memory area for the automatic
fault information reporting from the MP
built-in modem.
(1) 67
(2) XXX YYY
XXX: 000-299: Starting Memory Slot
No. in Block
YYY: 001-300: Number of Slots to be
assigned in Block
NOTE:
Assign more than two slots.
CM08
START
CM40
CM13
A
CM41
CM42
CM71
JULY/01/2006
REMOTE MAT
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Страница 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Страница 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Страница 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...