CHAPTER 2 TROUBLESHOOTING
– 133 –
NWA-008847-001 Rev.3.0
a6ch2001.fm
Lamp Indications on Circuit Cards
Continued on next page
KIND OF
CIRCUIT CARD
CARD NAME
LAMP
NAME
COLOR
INDICATIONS
NORMAL
ABNORMAL
Application
Processor Cards
PN-24PRTA
(PRT)
RUN
Green
120 IPM Flash
Steady ON or OFF
LC
Green
Steady ON
OFF
CRC
Red
OFF
Steady ON
PCM
Red
OFF
Steady ON
FRM
Red
OFF
Steady ON
RMT
Red
OFF
Steady ON
AIS
Red
OFF
Steady ON
PN-30PRTA
(PRT)
RUN
Green
120 IPM Flash
Steady ON or OFF
LC
Green
Steady ON
OFF
PCM
Red
OFF
Steady ON
FRM
Red
OFF
Steady ON
MFRM
Red
OFF
Steady ON
RMT
Red
OFF
Steady ON
MRMT
Red
OFF
Steady ON
AIS
Red
OFF
Steady ON
PN-4RSTB
(MFR)
RUN
Green
120 IPM Flash
Steady ON or OFF
PN-4RSTC
(CIR)
RUN
Green
120 IPM Flash
Steady ON or OFF
PN-4RSTF/
PN-4RSTF-A
(STD)
[For North
America]
BL3
Red
Steady ON
60 IPM Flash
BL2
Red
Steady ON
60 IPM Flash
BL1
Red
Steady ON
60 IPM Flash
BL0
Red
Steady ON
60 IPM Flash
PN-4RSTH
(SDT)
BL3
Red
Steady ON
60 IPM Flash
BL2
Red
Steady ON
60 IPM Flash
BL1
Red
Steady ON
60 IPM Flash
BL0
Red
Steady ON
60 IPM Flash
JULY/01/2006
FAULT DETECTION
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Страница 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Страница 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Страница 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...