– 734 –
NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE TITLE:
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
EA
NOTE 6:
Confirm the following fault information, when you check Remote Site operations by survival
mode as fault information from MAT/CAT in Remote PIM over IP.
01: System Initialization
42: Communication error occurrence between Main Site and Remote Site
52: Communication error restoration between Main Site and Remote Site
When Remote Site starts the survival mode operation, the fault information “Initialize by CAT
or MAT” (Fault occurrence kind No. 01) is registered to the MP card of Remote Site. In ad-
dition, “Communication error occurrence between Main Site and Remote Site” (Fault occur-
rence kind No. 42) is registered to the MP card of Main Site at 20 seconds later from the
predetermined time set by CM0B Y=31-60>50.
Remote Site on survival mode checks at every 30 seconds if the communications to Main Site
are possible. When the Remote Site regards that the communications are possible, “Commu-
nication error restoration between Main Site and Remote Site” (Fault occurrence kind No.
52) is registered to the MP card of Main Site at 20 seconds later from the predetermined time
set by CM0B Y=31-60>51.
[Series 3200 R6.2 (R6.2)]
NOTE 7:
About long call duration of trunk call (fault kind: 4A/4B)
• When Long call duration failure occurs, “Failure occurred” is displayed on the
MATWorX.
• After a trunk is seized, when the trunk is seized longer time than the monitoring time (1-60
hours) set by CM42>182, the call is registered as long call duration failure. However,
there is a tolerance up to 30 minutes between monitoring time set by office data and actual
time to be registered.
• Long call duration-2 (4B) is effective only when fault information store setting (CMEA
Y=2>4A: 1/2) of Long call duration-1 (4A) is set.
• Long call duration-2 (4B) is registered in any of the following cases:
- When receiving the Calling Party No. from the office
- When setting of MP Built-in SMDR is effective
[Series 3900]
NOTE 8:
The External Alarm Kind for “Number of faulty trunks was less than predetermined number”
is fixed to No Alarm. In the case of this office data, even if the 2nd data is set to 0/1/2/3, it
simply means that the fault information is to be registered into Fault Memory. In this case,
External Alarm Kind cannot be changed.
JUNE/01/2007
CMEA
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008844 001 ISSUE 5 0 Command Manual ...
Страница 24: ... viii NWA 008844 001 Rev 5 0 91toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006 ...
Страница 46: ... 22 NWA 008844 001 Rev 5 0 91ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY DECEMBER 02 2005 ...
Страница 66: ... 42 NWA 008844 001 Rev 5 0 91ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY DECEMBER 02 2005 ...
Страница 908: ... 884 NWA 008844 001 Rev 5 0 91ch3009 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 01 2007 ...
Страница 988: ... 964 NWA 008844 001 Rev 5 0 91ch4001 fm THIS PAGE LEFT BLANK INTENTIONALLY DECEMBER 02 2005 ...
Страница 1012: ... A24 NWA 008844 001 Rev 5 0 91apa001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...