CHAPTER 2 PRECAUTION
– 38 –
NWA-008844-001 Rev.5.0
91ch2001.fm
PASSWORD ENTRY
In a system with password service, a maintenance person is required to enter a authorization level number
(Password Level) and appropriate password prior to engaging in programming the system data with the
MAT/CAT. A maximum of eight (8) Password Levels can be set up. The number of commands that the
maintenance person can access is determined by the Password Level.
Password and accessible commands for each Password Level is determined by system data.
The procedure for programming, with password, is shown below.
STEP1:
Connect the MAT to the system, and turn the power switch on.
For the CAT, change the mode to CAT.
STEP2:
Enter the password (assigned by CME9>0-7) by CM03.
Operation:
– “OK” will be displayed, if accepted.
In case of “DATA ERROR”, the password is incorrect.
STEP3:
Start programming.
STEP4:
When programming is completed, set the following data by CM03.
Operation:
– Programming without password is restricted.
NOTE:
For the details of data assignment for password service, refer to CME7, CME9 on Chapter 3
Command Description.
+ 03 +
+ Password Level No. +
+ Pa
ST
EXE
DE
DE
+ 03 +
+ 9 +
+ CC
8 digits
EXE
ST
DE
DE
PASSWORD ENTRY
Содержание UNIVERGE NEAX 2000 IPS
Страница 1: ...NWA 008844 001 ISSUE 5 0 Command Manual ...
Страница 24: ... viii NWA 008844 001 Rev 5 0 91toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006 ...
Страница 46: ... 22 NWA 008844 001 Rev 5 0 91ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY DECEMBER 02 2005 ...
Страница 66: ... 42 NWA 008844 001 Rev 5 0 91ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY DECEMBER 02 2005 ...
Страница 908: ... 884 NWA 008844 001 Rev 5 0 91ch3009 fm THIS PAGE LEFT BLANK INTENTIONALLY JUNE 01 2007 ...
Страница 988: ... 964 NWA 008844 001 Rev 5 0 91ch4001 fm THIS PAGE LEFT BLANK INTENTIONALLY DECEMBER 02 2005 ...
Страница 1012: ... A24 NWA 008844 001 Rev 5 0 91apa001 fm THIS PAGE LEFT BLANK INTENTIONALLY ...