Minimum
100 mm
(3.937)
Minimum
100 mm
(3.937)
Minimum
100 mm
(3.937)
Minimum
300 mm
(11.811)
Minimum
300 mm
(11.811)
Ceiling
Floor
Wall
Minimum 200 mm (7.874)
for ventilation
Minimum 200 mm (7.874)
for ventilation
Main KSU
EXP. KSU
EXP. KSU
EXP. KSU
Figure 2-4 Horizontal Arrangement of KSUs
Due to the limit of extension cable length to connect between Main KSU and Expansion KSU(s), the install
location of Main KSU and each Expansion KSU(s) must be considered as
Arrangement of KSUs on page 2-6
.
1.3.3 Mounting Procedure of KSU
One Main KSU or Expansion KSU(s) can be mounted per IP4WW-Battery Box. For the mounting, refer to
Mounting One KSU on the Battery Box on page 2-33
.
1.
Place the attached template on the wall to mark the four screw positions.
UP
Template
Figure 2-5 Wall-Mounting Template
SL1000
ISSUE 3.0
2-6
Installation