S
ECTION
2 SYSTEM SPECIFICATIONS
2.1 General Precautions
• Never attempt to insert wires, pins, etc. into the vents or other holes of the equipment.
• Do not use benzene, thinner, or the like, or any abrasive powder to clean the equipment. Wipe it
with a soft cloth.
2.2 Environmental Requirements
Meeting established environmental standards maximizes the life of the system. Be sure that the site is
not:
• In direct sunlight or in hot, cold or humid places.
• In dusty areas or in areas where sulfuric gases are produced.
• In places where shocks or vibrations are frequent or strong.
• In places where water or other fluids comes in contact with the equipment.
• In areas near high-frequency machines or electric welders.
• Near computers, telexes, microwaves, air conditioners, etc.
• Near radio antennas (including shortwave)
2.3 Operating Conditions
Table 5-2 Operating Conditions
Unit
Operating Conditions
KSU, PCBs and Multiline Telephones
Temperature: 0 to +40 degree C (32 to 104 degree F)
Humidity: 10 to 90% (non-condensing)
Doorphone Box
Temperature: -20 to +60 degree C (-4 to 140 degree F)
Humidity: 20 to 80% (non-condensing)
2.4 Site Requirements
A KSU can only be wall-mounted, it can only be floor-mounted if the optional External Backup Battery
Box is installed.
2.5 AC Power Requirement
A dedicated 100V-120V/220V/230V/240V 50/60Hz circuit located within 2 meters of the KSU is
required. A separate dedicated AC outlet is necessary for each KSU.
Double Pole/Neutral Fusing
(Power supply fuses are located at both the L and N side.)
Table 5-3 Power Requirement
110 VAC
220 VAC
230 VAC
240 VAC
Power Require-
ments
110 VAC@15 A
220 VAC@15 A
230 VAC@15 A
240 VAC@15 A
Power Con-
sumption
Main KSU = 144 VA
4 KSU Total = 576 VA
Main KSU = 172 VA
4 KSU Total = 688 VA
Main KSU = 175 VA
4 KSU Total = 700 VA
Main KSU = 175 VA
4 KSU Total = 700 VA
Input Voltage
(Rated Voltage)
90 VAC to 264 VAC (100VAC/120VAC/220VAC/230VAC/240VAC)
ISSUE 3.0
SL1000
Hardware Manual
5-3
Содержание SL1000
Страница 1: ...Hardware Manual A50 031170 001 GE ISSUE 3 0 November 2012...
Страница 12: ...MEMO SL1000 ISSUE 3 0 x Hardware Manual...
Страница 16: ...MEMO SL1000 ISSUE 3 0 R 4 Regulatory...
Страница 126: ...MEMO SL1000 ISSUE 3 0 3 8 System Start Up...
Страница 140: ...MEMO SL1000 ISSUE 3 0 4 14 Maintenance...
Страница 149: ...MEMO ISSUE 3 0 SL1000 Hardware Manual 5 9...
Страница 150: ...Hardware Manual NEC Corporation ISSUE 3 0...